0154001.DR
리틀퓨즈(주)
- Lifecycle
- Active
- Stock
- 4698 PCS
- Series
- 퓨즈
0154001.DR과 0154004.DR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The 0154001.DR is a lower-current-rated alternative to the 0154004.DR within the same Littelfuse OMNI-BLOK fuse holder series. Both share identical fusing characteristics, voltage rating, and PCB mounting footprint, making the 0154001.DR a viable functional replacement candidate where the reduced current rating is acceptable for the target application.
리틀퓨즈(주)
리틀퓨즈(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | 0154004.DR | 0154001.DR | Why it matters |
|---|---|---|---|
| Current Rating | 4 A | 1 A | Determines the maximum continuous current the fuse can carry without opening; a direct functional difference affecting circuit protection sizing. |
| Voltage Rating (AC) | 125 V | 125 V | Specifies the maximum AC voltage the fuse can safely interrupt; must meet or exceed the circuit voltage. |
| Voltage Rating (DC) | 125 V | 125 V | Specifies the maximum DC voltage the fuse can safely interrupt; critical for DC-powered circuits. |
| Interrupting Rating | 50 A at 125 VAC / 50 A at 125 VDC | 50 A at 125 VAC / 50 A at 125 VDC | Indicates the maximum fault current the fuse can safely break without damage or hazard. |
| Melting I²t | 12.8 A²s | 0.58 A²s | Represents the thermal energy required to open the fuse; affects response time and coordination with other protective devices. |
| Nominal Cold Resistance | 0.0185 Ohm | 0.145 Ohm | Lower resistance reduces voltage drop and power loss in the circuit; impacts overall efficiency. |
| Voltage Drop | 0.095 V | 0.175 V | Affects the voltage available to the load and heat generation within the fuse. |
| Fuse Type | Time-Lag (Slow-Blow) | Time-Lag (Slow-Blow) | Determines tolerance to inrush currents; must match the application's surge characteristics. |
| Package / Size | 1206 (3216 Metric) | 1206 (3216 Metric) | Physical footprint must match the PCB layout for direct substitutability. |
| Operating Temperature Range | -55°C to +125°C | -55°C to +125°C | Ensures reliable operation across the application's environmental conditions. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | 0154001.DR | 0154004.DR |
|---|---|---|
| Series | OMNI-BLOK® 154 | OMNI-BLOK® 154 |
| Part Status | Active | Active |
| Mounting Type | Requires Holder, Surface Mount | Holder, Surface Mount |
| Fuse Type | Board Mount (Cartridge Style Excluded) | Board Mount (Cartridge Style Excluded) |
| Current Rating (Amps) | 1 A | 4 A |
| Voltage Rating - AC | 125 V | 125 V |
| Voltage Rating - DC | 125 V | 125 V |
| Response Time | Fast Blow | Fast Blow |
| Breaking Capacity @ Rated Voltage | 50A | 50A |
| Melting I²t | 0.459 | 3.152 |
| Approval Agency | PSE, UL | PSE, UL |
| Operating Temperature | -55°C ~ 125°C | -55°C ~ 125°C |
| Color | Tan | - |
| Size / Dimension | 0.383" L x 0.198" W x 0.150" H (9.73mm x 5.03mm x 3.81mm) | - |
| Packaging | Cut Tape (CT), Tape & Reel (TR) | - |
The 0154004.DR and 0154001.DR are Littelfuse surface-mount fuses from the NANO2 154 series. The 0154004.DR is rated 4 A and the 0154001.DR is rated 1 A, both with a 125 V AC/VDC voltage rating and a 6.1 mm x 2.69 mm ceramic body.
The primary difference is the current rating: the 0154004.DR is a 4 A fuse, while the 0154001.DR is a 1 A fuse. Both share the same NANO2 154 series package, voltage rating, and interrupting rating, so they differ mainly in the overcurrent level at which they open.
No. Although they share the same footprint and voltage rating, their current ratings differ by a factor of four. Substituting one for the other would change the circuit's overcurrent protection threshold and could cause nuisance opening or failure to protect, so each must be selected according to the design's required current rating.
Both the 0154004.DR and 0154001.DR are rated for 125 V AC and 125 V DC, as specified in the Littelfuse NANO2 154 series datasheet.
Both fuses have an interrupting rating of 50 A at 125 V AC and 50 A at 125 V DC, per the Littelfuse NANO2 154 series specifications.
Both are surface-mount NANO2 fuses in a ceramic body measuring approximately 6.1 mm x 2.69 mm, supplied on tape and reel for automated PCB assembly.
Yes. Both the 0154004.DR and 0154001.DR are specified for operation from -55 °C to +125 °C, consistent with the Littelfuse NANO2 154 series datasheet.
The 0154001.DR at 1 A is suited to lower-current circuits, while the 0154004.DR at 4 A is suited to higher-current circuits. Selection should be based on the continuous operating current, inrush profile, and required breaking capacity of the target design, using the manufacturer's derating and time-current curves.