1812L110/33MR
리틀퓨즈(주)
- Lifecycle
- Active
- Stock
- 5657 PCS
- Package
- 1812 (4532 Metric), Concave
- Series
- PTC 재설정 퓨즈
1812L110/33MR과 1812L014DR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The 1812L014DR and 1812L110/33MR are both 1812-package PPTC resettable fuses, but they are not functionally interchangeable. The 1812L014DR is a low-hold-current device intended for sensitive, low-power circuit protection, while the 1812L110/33MR is a high-current, high-voltage-rated device designed for substantially higher fault-energy environments. Their divergent hold current, trip current, voltage rating, and time-to-trip characteristics make direct substitution inadvisable without a full circuit re-evaluation.
리틀퓨즈(주)
리틀퓨즈(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | 1812L014DR | 1812L110/33MR | Why it matters |
|---|---|---|---|
| Hold Current (Ih) | 0.14 A | 1.10 A | Defines the maximum continuous current the device passes without tripping; a higher hold current allows more load current before protection activates. |
| Trip Current (It) | 0.34 A | 2.20 A | The minimum current guaranteed to trip the device; it sets the threshold above which overcurrent protection reliably engages. |
| Maximum Voltage Rating | 60 V | 33 V | The highest voltage the device can withstand while tripped; it must exceed the circuit's maximum operating voltage for safe protection. |
| Maximum Interrupt Current | 10 A | 40 A | The largest fault current the device can safely interrupt; higher ratings provide robustness against severe short-circuit events. |
| Initial Resistance (Rmin) | 1.5 Ω | 0.06 Ω | Lower resistance reduces voltage drop and power loss in normal operation, which is critical for higher-current circuits. |
| Post-Trip Resistance (R1max) | 6.0 Ω | 0.20 Ω | Maximum resistance after tripping affects residual voltage drop and heat generation once the device resets. |
| Time to Trip at Rated Current | 0.15 s | 0.50 s | Response speed determines how quickly the device protects downstream components during an overcurrent event. |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | Defines the ambient conditions under which the device maintains its specified electrical characteristics. |
| Package / Size | 1812 (4532 metric) | 1812 (4532 metric) | Physical footprint must match the PCB land pattern for direct drop-in substitution. |
| Mounting Type | Surface Mount | Surface Mount | Assembly method must be compatible with the manufacturing process and board design. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | 1812L110/33MR | 1812L014DR |
|---|---|---|
| Series | POLY-FUSE®, 1812L | POLY-FUSE®, 1812L |
| Part Status | Active | Active |
| Type | Polymeric | Polymeric |
| Voltage - Max | 33V | 60V |
| Current - Max | 20 A | 10 A |
| Current - Hold(Ih)(Max) | 1.1 A | 140 mA |
| Current - Trip(It) | 1.95 A | 340 mA |
| Timeto Trip | 500 ms | 150 ms |
| Resistance - Initial(Ri)(Min) | 60 mOhms | 1.5 Ohms |
| Resistance - Post Trip(R1)(Max) | 200 mOhms | 6 Ohms |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
| Size / Dimension | 0.179 L x 0.128 W (4.55mm x 3.24mm) | 0.179 L x 0.128 W (4.55mm x 3.24mm) |
| Thickness(Max) | 0.079 (2.00mm) | 0.077 (1.95mm) |
The 1812L014DR is a 1812-size polyfuse with a hold current of 0.14 A and a maximum voltage rating of 60 V, while the 1812L110/33MR is a 1812-size polyfuse with a hold current of 1.10 A and a maximum voltage rating of 33 V. The 1812L014DR is designed for lower-current, higher-voltage circuits, whereas the 1812L110/33MR is designed for higher-current, lower-voltage circuits.
No, they are not directly interchangeable. The 1812L014DR has a hold current of 0.14 A and a trip current of 0.28 A, while the 1812L110/33MR has a hold current of 1.10 A and a trip current of 2.20 A. Substituting one for the other would result in incorrect overcurrent protection and potential circuit malfunction or damage.
The 1812L014DR has a maximum voltage rating of 60 V, and the 1812L110/33MR has a maximum voltage rating of 33 V. These ratings must not be exceeded in the application.
The 1812L014DR has a hold current of 0.14 A at 20°C and a trip current of 0.28 A at 20°C, with a maximum time-to-trip of 0.15 s at 0.70 A.
The 1812L110/33MR has a hold current of 1.10 A at 20°C and a trip current of 2.20 A at 20°C, with a maximum time-to-trip of 0.50 s at 5.50 A.
Yes, both the 1812L014DR and the 1812L110/33MR are supplied in the 1812 (4532 metric) surface-mount package, with compatible pad layouts and dimensions as specified in their respective datasheets.
The 1812L014DR is typically used in low-current, higher-voltage circuits such as industrial control, telecommunications, and battery chargers. The 1812L110/33MR is typically used in higher-current, lower-voltage circuits such as USB peripherals, portable electronics, and power supplies.
Both the 1812L014DR and the 1812L110/33MR are rated for an operating temperature range of -40°C to +85°C, as specified in their manufacturer datasheets.