ACPL-C784-500E
브로드컴 유한회사
- Lifecycle
- Active
- Stock
- 6380 PCS
- Package
- SSO-8
- Series
- 선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기
ACPL-C784-500E과 ACPL-C78A-060E에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ACPL-C784-500E and ACPL-C78A-060E are both isolated analog amplifiers from Broadcom's ACPL-C78x series, sharing the same core architecture, isolation performance, and gain characteristics. The ACPL-C784-500E is supplied in a surface-mount SO-8 package with tape-and-reel packaging, while the ACPL-C78A-060E is supplied in a through-hole DIP-8 package. The primary distinction lies in the package mounting style and the specified gain tolerance grade, which may affect direct board-level interchangeability without layout adaptation. Designers should verify mechanical compatibility and gain accuracy requirements before substituting one for the other.
브로드컴 유한회사
브로드컴 유한회사
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ACPL-C784-500E | ACPL-C78A-060E | Why it matters |
|---|---|---|---|
| Manufacturer | Broadcom | Broadcom | Same manufacturer ensures consistent quality, documentation, and support. |
| Product Category | Isolation Amplifier | Isolation Amplifier | Both belong to the same functional category, indicating they serve similar signal-isolation roles. |
| Number of Channels | 1 | 1 | Channel count must match the circuit's signal path requirements for direct substitution. |
| Isolation Voltage | 5000 Vrms | 5000 Vrms | Isolation voltage determines the safety barrier rating between high- and low-voltage domains. |
| Input Type | DC | DC | Input type must match the signal source to ensure proper operation. |
| Output Type | Differential | Differential | Output type must be compatible with the downstream ADC or signal-conditioning stage. |
| Supply Voltage | 4.5 V to 5.5 V | 4.5 V to 5.5 V | Supply voltage range must match the available power rail for drop-in compatibility. |
| Operating Temperature Range | -40°C to +105°C | -40°C to +105°C | Temperature range must cover the application's environmental conditions for reliable operation. |
| Package / Mounting | Surface Mount, 8-SO Stretched | Surface Mount, 8-SO Stretched | Package and mounting style must match the PCB footprint for physical interchangeability. |
| Packaging Option | Tape & Reel | Tube | Packaging affects assembly-line handling and reflow/placement processes. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ACPL-C784-500E | ACPL-C78A-060E |
|---|---|---|
| Supplier | - | Broadcom Limited |
| Part Status | Active | Active |
| Amplifier Type | Isolation | Isolation |
| Number of Circuits | 1 | 1 |
| Output Type | Differential | Differential |
| -3 dB Bandwidth | 100 kHz | 100 kHz |
| Voltage - Input Offset | 300 µV | 300 µV |
| Supply Current | 11mA | 11mA |
| Current - Output / Channel | 18.6 mA | 18.6 mA |
| Voltage - Supply Span(Min) | 4.5 V | 4.5 V |
| Voltage - Supply Span(Max) | 5.5 V | 5.5 V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
Both are Broadcom ACPL-C78x series optically isolated sigma-delta modulator amplifiers designed for isolated current and voltage sensing in motor control, power conversion, and industrial applications. The ACPL-C784-500E is supplied in a 16-lead SOIC wide-body package and is delivered in tape-and-reel packaging (suffix 500E), while the ACPL-C78A-060E is supplied in a 16-lead SOIC wide-body package with a tube packaging option (suffix 060E).
The primary differences are the ordering suffix and packaging format. The ACPL-C784-500E uses the 500E tape-and-reel option, while the ACPL-C78A-060E uses the 060E tube option. Both share the same ACPL-C78x functional core, isolated sigma-delta modulator architecture, and 16-lead SOIC wide-body package footprint. Electrical specifications should be verified against the respective Broadcom datasheet for the exact ordering part number.
Yes. Both devices are offered in the same 16-lead SOIC wide-body package with the same pinout, so they are pin-compatible at the package level. However, designers should confirm the exact pin functions and any datasheet-specific notes for each ordering part number before substituting one for the other in an existing design.
Broadcom ACPL-C78x series isolated sigma-delta modulators are specified with a 5 kVrms isolation rating for the wide-body SOIC package, with UL, CSA, and IEC/EN/DIN EN 60747-5-5 recognition. The exact isolation parameters, working voltage, and transient immunity should be confirmed from the official Broadcom datasheet for the specific ordering part number.
These ACPL-C78x devices are designed for a nominal ±200 mV input signal range with a 5 V supply on the isolated side and a 3.3 V or 5 V supply on the non-isolated side, depending on the specific configuration. The exact recommended operating conditions, input range, and supply voltage limits must be verified from the Broadcom datasheet for the exact ordering part number.
Because both parts share the same ACPL-C78x functional core and 16-lead SOIC wide-body package, they are electrically and mechanically interchangeable in most designs. The only difference is the packaging option (tape-and-reel versus tube). Designers should still validate the exact ordering part number against the target design requirements and the manufacturer datasheet before substitution.
Broadcom ACPL-C78x series isolated modulators carry UL 1577 recognition, CSA component acceptance, and IEC/EN/DIN EN 60747-5-5 approval for reinforced insulation. The specific certification file numbers and approval conditions should be confirmed from the official Broadcom datasheet and the respective certification bodies for the exact ordering part number.
Typical applications include isolated current sensing in motor drives and inverters, isolated voltage sensing in power supplies and solar inverters, industrial process control, and other systems requiring galvanic isolation between high-voltage and low-voltage domains. Both ordering part numbers are suitable for these applications because they share the same ACPL-C78x functional core.