ACPL-C790-500E
브로드컴 유한회사
- Lifecycle
- Active
- Stock
- 5096 PCS
- Package
- SSO-8
- Series
- 선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기
ACPL-C790-500E과 ACPL-C780-560E에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ACPL-C790-500E and ACPL-C780-560E are both isolated sigma-delta modulator optocouplers from Broadcom's ACPL-C79x/C78x family, sharing the same 8-pin stretched SO-8 footprint, 5 V supply, and ±1% gain tolerance architecture. The ACPL-C790-500E offers a wider specified operating temperature range and tighter gain error specification, making it a viable functional replacement for the ACPL-C780-560E in most isolated current-sensing applications, provided the system-level gain and offset calibration is re-validated for the target design.
브로드컴 유한회사
브로드컴 유한회사
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ACPL-C790-500E | ACPL-C780-560E | Why it matters |
|---|---|---|---|
| Manufacturer Part Number | ACPL-C790-500E | ACPL-C780-560E | Identifies the exact orderable device; the suffix encodes gain tolerance and packaging, which affect direct substitutability. |
| Gain Tolerance | ±1% | ±3% | Tighter gain tolerance improves measurement accuracy and reduces calibration effort in current-sensing applications. |
| Input Offset Voltage | ±0.6 mV typical | ±0.6 mV typical | Low offset voltage minimizes error at low sensed currents, affecting accuracy near zero load. |
| Isolation Voltage | 5000 Vrms | 5000 Vrms | Determines the safe galvanic isolation barrier between high-voltage and low-voltage circuitry. |
| Bandwidth | 200 kHz | 200 kHz | Sets the maximum signal frequency the amplifier can faithfully pass, impacting dynamic response in motor and inverter control. |
| Supply Voltage Range | 4.5 V to 5.5 V | 4.5 V to 5.5 V | Defines the compatible power rails for the output side of the isolated amplifier. |
| Operating Temperature Range | -40°C to +105°C | -40°C to +105°C | Ensures reliable operation across industrial ambient conditions and thermal environments. |
| Package / Shipping Option | Stretched SO-8, tape and reel (500E) | Stretched SO-8, tape and reel (560E) | Packaging suffix affects reel size and pick-and-place handling, which matters for production line compatibility. |
| Output Type | Differential analog voltage | Differential analog voltage | Determines the interface to the downstream ADC or controller and whether signal conditioning is required. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ACPL-C790-500E | ACPL-C780-560E |
|---|---|---|
| Supplier | - | Broadcom Limited |
| Part Status | Active | Active |
| Amplifier Type | Isolation | Isolation |
| Number of Circuits | 1 | 1 |
| Output Type | Differential | Differential |
| -3 dB Bandwidth | 200 kHz | 100 kHz |
| Voltage - Input Offset | 600 µV | 300 µV |
| Supply Current | 13mA | 11mA |
| Current - Output / Channel | 11 mA | 18.6 mA |
| Voltage - Supply Span(Min) | 4.5 V | 4.5 V |
| Voltage - Supply Span(Max) | 5.5 V | 5.5 V |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
| Current - Input Bias | 100 nA | - |
The ACPL-C790-500E and ACPL-C780-560E are Broadcom isolation amplifiers designed for current sensing and voltage sensing in motor control, power conversion, and industrial applications. Both are optically isolated amplifiers that provide galvanic isolation between the high-voltage and low-voltage sides of a system.
The primary difference is the specified gain tolerance and package option. The ACPL-C790-500E offers a tighter gain tolerance of ±1%, while the ACPL-C780-560E has a gain tolerance of ±3%. The suffix codes also indicate different package and tape-and-reel options: the -500E denotes a 500 mil wide-body SO-8 package in tape and reel, and the -560E denotes a 560 mil wide-body SO-8 package in tape and reel.
No. The ACPL-C790-500E uses a 500 mil (12.7 mm) wide-body SO-8 package, while the ACPL-C780-560E uses a 560 mil (14.2 mm) wide-body SO-8 package. The different package widths result in different PCB land patterns and creepage/clearance dimensions, so they are not drop-in replacements for each other without layout changes.
Both the ACPL-C790-500E and ACPL-C780-560E are rated for 5 kV RMS isolation for 1 minute per UL 1577. The 560 mil wide-body package of the ACPL-C780-560E provides greater creepage and clearance distances compared to the 500 mil package, which can be advantageous in applications requiring higher working voltages or more stringent safety margins.
The ACPL-C790-500E has a specified input offset voltage of ±0.3 mV (typical) and a gain error of ±1% (maximum). The ACPL-C780-560E has a specified input offset voltage of ±0.5 mV (typical) and a gain error of ±3% (maximum). These differences make the ACPL-C790-500E more suitable for applications requiring higher accuracy current sensing.
Yes. Both devices operate from a single 5 V supply on the input side and a 3.3 V or 5 V supply on the output side, depending on the specific configuration. The recommended operating supply voltage range is 4.5 V to 5.5 V for the input side and 3.0 V to 5.5 V for the output side, as specified in the respective Broadcom datasheets.
The ACPL-C790-500E is generally better for high-precision motor current sensing due to its tighter gain tolerance of ±1% and lower typical input offset voltage of ±0.3 mV. The ACPL-C780-560E, with ±3% gain tolerance, is more suitable for applications where absolute accuracy is less critical but a wider package for higher creepage is required.
Yes. Both the ACPL-C790-500E and ACPL-C780-560E are certified to UL 1577 (5 kV RMS for 1 minute), CSA Component Acceptance Notice #5, and VDE 0884-10 (VDE 0884-10 is applicable to the 560 mil package for reinforced insulation). Designers should verify the specific certification file numbers and ratings in the latest Broadcom datasheet for each part number.