AD4115BCPZ
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 6823 PCS
- Series
- 데이터 수집 - 아날로그 변환기(ADC)
AD4115BCPZ과 AD4111BCPZ-RL7에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The AD4111BCPZ-RL7 and AD4115BCPZ are both single-supply, 24-bit sigma-delta ADCs in the same 40-lead LFCSP package, sharing a common architecture and SPI interface. However, they differ in analog input channel count, maximum input voltage range, and integrated diagnostic features, so the AD4115BCPZ is not a direct drop-in replacement for the AD4111BCPZ-RL7. Designers must validate channel count, input range, and system-level diagnostics before substituting one for the other.
아날로그 디바이스(주)
아날로그 디바이스(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD4111BCPZ-RL7 | AD4115BCPZ | Why it matters |
|---|---|---|---|
| Number of Input Channels | 4 differential / 8 single-ended | 8 differential / 16 single-ended | Channel count determines how many sensor signals can be digitized by a single device, directly affecting system scalability and board layout. |
| ADC Architecture | Sigma-Delta (24-bit) | Sigma-Delta (24-bit) | Both use sigma-delta conversion, providing high resolution and noise rejection suitable for precision industrial measurement. |
| Input Voltage Range | ±10 V (voltage inputs) | ±10 V (voltage inputs) | Matching input ranges ensures the same sensor signals can be interfaced without additional signal conditioning. |
| Current Input Support | Yes (0-20 mA / 4-20 mA) | No | Current input capability allows direct connection of industrial current-loop sensors, which is critical for process control applications. |
| Integrated Features | Voltage + current inputs, open-wire detection | Voltage inputs only | Integrated current inputs and diagnostics reduce external circuitry and simplify system design for mixed-signal applications. |
| Data Output Rate | Up to 31.25 kSPS | Up to 31.25 kSPS | Output rate determines the maximum sampling speed for dynamic signals and affects anti-aliasing filter requirements. |
| Interface | SPI | SPI | A standard SPI interface ensures compatibility with most microcontrollers and digital signal processors. |
| Supply Voltage | 2.7 V to 5.5 V (digital), ±15 V (analog) | 2.7 V to 5.5 V (digital), ±15 V (analog) | Compatible supply requirements allow the same power architecture to be used for either device. |
| Package | 40-lead LFCSP (6 mm x 6 mm) | 40-lead LFCSP (6 mm x 6 mm) | Identical package and footprint enable drop-in replacement without PCB redesign. |
| Operating Temperature Range | -40°C to +105°C | -40°C to +105°C | Industrial temperature range ensures reliable operation in harsh environments. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD4115BCPZ | AD4111BCPZ-RL7 |
|---|---|---|
| Part Status | Active | Active |
| Base Product Number | AD4115 | - |
| Number of Bits | 24 | 24 |
| Sampling Rate (Per Second) | 125k | - |
| Number of Inputs | 8, 16 | 4, 8 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | DSP, MICROWIRE™, QSPI™, and SPI™ | Serial, SPI |
| Configuration | MUX-ADC | MUX-S/H-ADC |
| Ratio - S / H: ADC | 0:1 | 0:1 |
| Number of A / D Converters | 1 | - |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External, Internal | External, Internal |
| Voltage - Supply, Analog | 4.5V ~ 5.5V | 2V ~ 5.5V |
| Voltage - Supply, Digital | 2V ~ 5.5V | 2V ~ 5.5V |
| Features | Temperature Sensor | Internal Oscillator, Temperature Sensor |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 105°C |
| Mounting Type | Surface Mount | - |
| Packaging | Tray | - |
| Sampling Rate(Per Second) | - | 6.2k |
| Number of A/D Converters | - | 1 |
The AD4111BCPZ-RL7 is a 24-bit, 8-channel, single-ended/differential, sigma-delta ADC with ±10 V and 0-10 V inputs, while the AD4115BCPZ is a 24-bit, 8-channel, single-ended/differential, sigma-delta ADC with ±10 V inputs only. The AD4111BCPZ-RL7 includes additional features such as open-wire detection and a voltage reference, whereas the AD4115BCPZ does not include open-wire detection.
No, they are not pin-compatible. The AD4111BCPZ-RL7 is available in a 40-lead LFCSP (6 mm × 6 mm) package, while the AD4115BCPZ is available in a 40-lead LFCSP (6 mm × 6 mm) package, but the pin functions differ due to the additional features of the AD4111BCPZ-RL7. Always consult the respective datasheets for pin configurations.
No, they are not direct replacements. The AD4111BCPZ-RL7 offers additional functionality such as open-wire detection and a voltage reference, which the AD4115BCPZ lacks. The input voltage ranges also differ: the AD4111BCPZ-RL7 supports ±10 V and 0-10 V, while the AD4115BCPZ supports only ±10 V. Design changes may be required.
The AD4111BCPZ-RL7 supports both ±10 V and 0-10 V input ranges. The AD4115BCPZ supports only ±10 V input ranges. Both devices are 24-bit sigma-delta ADCs with 8 channels.
No. The AD4111BCPZ-RL7 includes an internal voltage reference, while the AD4115BCPZ does not. The AD4115BCPZ requires an external voltage reference for operation.
Both the AD4111BCPZ-RL7 and AD4115BCPZ are offered in a 40-lead LFCSP (6 mm × 6 mm) package. However, the pin functions and internal features differ between the two devices.
The AD4111BCPZ-RL7 is better suited for applications requiring open-wire detection, as it includes this feature. The AD4115BCPZ does not support open-wire detection.
Both the AD4111BCPZ-RL7 and AD4115BCPZ are 24-bit sigma-delta ADCs with 8 channels. They support both single-ended and differential input configurations.