AD4115BCPZ-RL7 vs AD4114BCPZ

AD4115BCPZ-RL7과 AD4114BCPZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD4114BCPZ and AD4115BCPZ-RL7 are functionally compatible candidates for replacement, sharing identical package, pin count, and core architecture. Both are 24-bit sigma-delta ADCs with integrated analog front ends, differing primarily in input channel count and throughput rate. Designers should validate channel requirements and sampling rate needs before substituting, as the AD4115 offers higher channel density and faster output data rates than the AD4114.

Package Type High match
Resolution High match
Input Channel Count Validation required
Output Data Rate Validation required

Parts at a glance

Part A

AD4115BCPZ-RL7

아날로그 디바이스(주)

Lifecycle
Active
Stock
4071 PCS
Package
VFQFN-40
Series
데이터 수집 - 아날로그 변환기(ADC)
Part B

AD4114BCPZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
2561 PCS
Package
VFQFN-40
Series
데이터 수집 - 아날로그 변환기(ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD4114BCPZ AD4115BCPZ-RL7 Why it matters
Number of Input Channels 8 single-ended / 4 differential 16 single-ended / 8 differential Determines how many analog signals can be measured simultaneously, directly affecting system channel density and whether the part can substitute in multi-channel designs.
Resolution 24-bit 24-bit Both provide 24-bit resolution, so measurement precision is equivalent and not a barrier to substitution.
Maximum Sample Rate 31.25 kSPS 125 kSPS Higher throughput enables faster data acquisition; a slower device may bottleneck high-speed control loops or multiplexed measurement systems.
Input Voltage Range ±10 V ±10 V Matching input ranges means both can interface with the same industrial signal levels without additional conditioning circuitry.
Interface Type SPI SPI Identical serial interface simplifies firmware and hardware compatibility when swapping between the two devices.
Supply Voltage (Analog) 4.5 V to 5.5 V 4.5 V to 5.5 V Same analog supply requirements allow reuse of existing power rails and decoupling networks.
Package 40-Lead LFCSP (6x6 mm) 40-Lead LFCSP (6x6 mm) Identical footprint and package enable drop-in PCB compatibility without layout changes.
Operating Temperature Range -40°C to +105°C -40°C to +105°C Equivalent temperature ratings ensure both parts suit the same industrial and harsh-environment applications.
Integrated Features PGA, voltage reference, sequencer PGA, voltage reference, sequencer Shared on-chip signal conditioning reduces external component count and preserves system-level design compatibility.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD4115BCPZ-RL7 AD4114BCPZ
Part Status Active Active
Number of Bits 24 24
Sampling Rate(Per Second) 125k 31.25k
Number of Inputs 8, 16 8, 16
Input Type Differential, Single Ended Differential, Single Ended
Data Interface DSP, MICROWIRE™, QSPI™, and SPI™ DSP, MICROWIRE™, QSPI™, and SPI™
Configuration MUX-ADC MUX-ADC
Ratio - S / H: ADC 0:1 0:1
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External, Internal External, Internal
Voltage - Supply, Analog 4.5V ~ 5.5V 3V ~ 5.5V
Voltage - Supply, Digital 2V ~ 5.5V 2V ~ 5.5V
Features Temperature Sensor Temperature Sensor
Operating Temperature -40°C ~ 105°C -40°C ~ 105°C

Frequently asked questions

What are the key differences between the AD4114BCPZ and AD4115BCPZ-RL7?

The AD4114BCPZ is a 24-bit sigma-delta ADC with ±10 V inputs, 8 differential or 16 single-ended channels, and a maximum output data rate of 31.25 kSPS. The AD4115BCPZ-RL7 is a 24-bit sigma-delta ADC with ±10 V inputs, 8 differential or 16 single-ended channels, and a maximum output data rate of 125 kSPS. The AD4115 also offers a faster maximum output data rate and is supplied in a 40-lead LFCSP package in tape and reel packaging, while the AD4114BCPZ is supplied in a 40-lead LFCSP tray.

Are the AD4114BCPZ and AD4115BCPZ-RL7 pin-compatible?

Yes, both devices are offered in the same 40-lead LFCSP package with identical pin functions, allowing for a direct PCB layout drop-in replacement when the faster output data rate of the AD4115 is required.

Can the AD4114BCPZ be replaced by the AD4115BCPZ-RL7 without firmware changes?

In most cases, yes, because both devices share the same register map and SPI interface. However, the AD4115 supports a higher maximum output data rate, so firmware that relies on the AD4114's maximum rate of 31.25 kSPS will still function but will not benefit from the AD4115's faster 125 kSPS capability unless the configuration registers are updated.

What is the maximum output data rate of each device?

The AD4114BCPZ has a maximum output data rate of 31.25 kSPS. The AD4115BCPZ-RL7 has a maximum output data rate of 125 kSPS.

Do both devices support the same input voltage range?

Yes, both the AD4114BCPZ and AD4115BCPZ-RL7 support ±10 V analog input ranges, as well as other programmable gain settings, making them suitable for industrial process control and instrumentation applications.

What are the package and packaging differences between the AD4114BCPZ and AD4115BCPZ-RL7?

Both devices are housed in a 40-lead LFCSP package. The AD4114BCPZ is typically supplied in a tray, while the AD4115BCPZ-RL7 is supplied in tape and reel packaging, which is suitable for automated pick-and-place assembly lines.

Which device is better for high-speed data acquisition systems?

The AD4115BCPZ-RL7 is better suited for high-speed data acquisition because its maximum output data rate of 125 kSPS is four times faster than the AD4114BCPZ's 31.25 kSPS, allowing faster sampling of analog signals without compromising resolution.

Are the AD4114BCPZ and AD4115BCPZ-RL7 functionally equivalent for low-speed precision measurements?

Yes, for low-speed precision measurements both devices provide 24-bit resolution and similar noise performance. The AD4114BCPZ is fully sufficient when the required output data rate is at or below 31.25 kSPS, while the AD4115BCPZ-RL7 offers additional headroom for faster measurements.