AD549JHZ vs AD549LHZ

AD549JHZ과 AD549LHZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD549LHZ and AD549JHZ are functionally equivalent electrometer-grade operational amplifiers that share the same core architecture, package, and pinout. The AD549LHZ offers tighter input offset voltage and offset voltage drift specifications, making it the preferred choice for applications demanding the highest DC precision. Both devices are viable substitutes in the same circuit, provided the designer validates that the AD549JHZ's looser offset limits remain acceptable for the target application.

Input Offset Voltage Grade Validation required
Package Type High match
Pin Configuration High match
Operating Temperature Range High match

Parts at a glance

Part A

AD549JHZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
3803 PCS
Package
TO-99-8
Series
선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기
Part B

AD549LHZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
1538 PCS
Package
TO-99
Series
선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD549LHZ AD549JHZ Why it matters
Input Offset Voltage (VOS) max 0.5 mV 1.0 mV Lower offset voltage improves DC accuracy in precision electrometer and low-level signal applications.
Input Offset Voltage Drift (TCVOS) max 10 µV/°C 20 µV/°C Lower drift maintains accuracy over temperature, critical for stable long-term measurements.
Input Bias Current (IB) max 60 fA 150 fA Ultra-low bias current is essential for high-impedance sensors, pH probes, and electrometer front ends.
Input Offset Current (IOS) max 30 fA 75 fA Lower offset current reduces error in high-source-impedance measurement circuits.
Input Noise Voltage (0.1 Hz to 10 Hz) typ 4 µV p-p 4 µV p-p Low 1/f noise is important for resolving small DC signals in precision instrumentation.
Common-Mode Rejection Ratio (CMRR) min 90 dB 80 dB Higher CMRR rejects common-mode interference, improving accuracy in noisy environments.
Power Supply Rejection Ratio (PSRR) min 90 dB 80 dB Better PSRR reduces sensitivity to supply variations, aiding precision performance.
Operating Temperature Range -40 °C to +85 °C 0 °C to +70 °C Wider temperature range enables use in industrial and outdoor applications.
Package / Grade TO-99, L Grade (industrial) TO-99, J Grade (commercial) Grade determines guaranteed specifications and suitable application environments.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD549JHZ AD549LHZ
Series Topgate™ Topgate™
Part Status Active Active
Amplifier Type General Purpose General Purpose
Number of Circuits 1 1
Slew Rate 3V/µs 3V/µs
Gain Bandwidth Product 1 MHz 1 MHz
Current - Input Bias 0.15 pA 0.04 pA
Voltage - Input Offset 500 µV 300 µV
Supply Current 600µA 600µA
Current - Output / Channel 20 mA 20 mA
Voltage - Supply Span(Min) 10 V 10 V
Voltage - Supply Span(Max) 36 V 36 V
Operating Temperature 0°C ~ 70°C 0°C ~ 70°C
Mounting Type Through Hole Through Hole

Frequently asked questions

What are the main differences between the AD549LHZ and AD549JHZ?

The AD549LHZ and AD549JHZ are both ultralow input bias current operational amplifiers from Analog Devices. The primary difference is their specified input offset voltage (Vos) grade. The AD549LHZ is the higher-grade version with a maximum input offset voltage of 1.0 mV, while the AD549JHZ has a maximum input offset voltage of 2.0 mV. Both are specified over the commercial temperature range and are available in a TO-99 hermetic metal can package.

Are the AD549LHZ and AD549JHZ pin-compatible?

Yes. Both the AD549LHZ and AD549JHZ are offered in the same TO-99 (H-08) hermetic metal can package with identical pin configurations. This allows them to be used interchangeably on the same PCB footprint without layout changes.

What is the input bias current specification for the AD549LHZ and AD549JHZ?

Both the AD549LHZ and AD549JHZ feature an ultralow maximum input bias current of 60 fA (0.06 pA) at 25°C, making them suitable for electrometer-grade applications. The typical input bias current is 10 fA at 25°C. These specifications are identical for both grades.

Can the AD549JHZ be used as a direct replacement for the AD549LHZ?

In many applications, yes, because both share the same pinout, package, and most electrical specifications. However, the AD549JHZ has a looser maximum input offset voltage (2.0 mV vs. 1.0 mV for the AD549LHZ). If the circuit requires the tighter offset voltage guaranteed by the L grade, the J grade may not meet the design margin without recalibration or offset trimming.

What is the operating temperature range for the AD549LHZ and AD549JHZ?

Both the AD549LHZ and AD549JHZ are specified for the commercial temperature range of 0°C to +70°C. They are not specified for industrial or military temperature ranges. For extended temperature operation, other grades or models would be required.

Do the AD549LHZ and AD549JHZ differ in input offset voltage drift?

Yes. The AD549LHZ has a maximum input offset voltage drift of 5 µV/°C, while the AD549JHZ has a maximum drift of 10 µV/°C. This difference is a direct consequence of the offset voltage grade and should be considered in precision applications where temperature stability is critical.

Are the AD549LHZ and AD549JHZ RoHS compliant?

The AD549LHZ and AD549JHZ are both available in lead-free, RoHS-compliant versions. The "Z" suffix in the part number indicates a RoHS-compliant package. However, designers should verify the specific ordering code and manufacturer documentation to confirm compliance for their exact lot or date code.

What are the common applications for the AD549LHZ and AD549JHZ?

Both grades are used in applications requiring ultralow input bias current, such as electrometer amplifiers, photodiode preamplifiers, pH electrode buffers, ionization chambers, and vacuum tube grid current measurement. The AD549LHZ is preferred where tighter offset voltage and lower drift are needed, while the AD549JHZ may be sufficient for less demanding precision requirements.