AD590MH
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 6424 PCS
- Package
- TO-52-3
- Series
- 온도 센서 - 아날로그 및 디지털 출력
AD590MH과 AD590JH에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The AD590MH is a functionally compatible replacement candidate for the AD590JH, sharing the same temperature-to-current output topology, package footprint, and supply range, with the MH grade offering a tighter linearity specification over the full military temperature range. Designers should confirm the tighter accuracy class and extended temperature grade align with their application requirements before substituting.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD590JH | AD590MH | Why it matters |
|---|---|---|---|
| Temperature Accuracy (Calibration Error at 25°C) | ±5.0°C max | ±0.5°C max | Determines the initial uncalibrated measurement error; the MH grade offers roughly 10x tighter accuracy, which is critical for precision sensing without individual trimming. |
| Grade / Accuracy Class | J grade (standard) | M grade (high accuracy) | The grade defines the guaranteed error budget and screening level; substituting a J for an M (or vice versa) changes system accuracy expectations. |
| Operating Temperature Range | -55°C to +150°C | -55°C to +150°C | Both cover the full military-grade range, so environmental capability is equivalent and not a differentiator for substitutability. |
| Nonlinearity | ±0.3°C max (over rated range) | ±0.3°C max (over rated range) | Nonlinearity sets the deviation from ideal output-versus-temperature slope; identical values mean linearity performance is the same across both grades. |
| Output Current Sensitivity | 1 µA/K | 1 µA/K | The 1 µA/K transfer function is the core interface characteristic; matching values ensures the same signal conditioning and readout circuitry can be reused. |
| Supply Voltage Range | +4 V to +30 V | +4 V to +30 V | Defines compatible power rails; identical ranges mean either part can drop into the same supply design. |
| Package | TO-52 (metal can) | TO-52 (metal can) | Footprint and thermal mounting must match for a drop-in replacement; identical packages allow direct board substitution. |
| Long-Term Drift | ±0.1°C max (per datasheet) | ±0.1°C max (per datasheet) | Drift affects stability over time; equal specifications indicate comparable long-term reliability for both grades. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD590MH | AD590JH |
|---|---|---|
| Part Status | Active | Active |
| Sensor Type | Analog, Local | Analog, Local |
| Sensing Temperature - Local | -55°C ~ 150°C | -55°C ~ 150°C |
| Output Type | Analog Current | Analog Current |
| Voltage - Supply | 4V ~ 30V | 4V ~ 30V |
| Accuracy - Highest(Lowest) | ±0.5°C | ±5°C |
| Test Condition | 25°C | 25°C |
| Operating Temperature | -55°C ~ 125°C | -55°C ~ 125°C |
| Mounting Type | Through Hole | Through Hole |
The main difference is the specified accuracy grade over the full operating temperature range. The AD590MH is a higher-grade version with tighter calibration and linearity error specifications compared to the AD590JH, making it suitable for applications requiring greater measurement precision.
Both the AD590JH and AD590MH are specified for the full military temperature range of -55°C to +150°C, allowing them to be used in harsh environments.
Yes, both devices are offered in the same hermetic TO-52 package (H package) and share the identical pinout, allowing them to be used interchangeably on the same PCB footprint.
Both are two-terminal current-output temperature transducers that produce an output current proportional to absolute temperature, with a nominal scale factor of 1 µA/K.
Both devices operate over a supply voltage range of +4 V to +30 V, providing flexibility in system power design.
Yes, the AD590MH is a drop-in replacement for the AD590JH in terms of package and pinout, and it offers improved accuracy specifications. The system should be validated to confirm that the tighter error limits meet the application requirements.
The AD590JH has a specified calibration error of ±5.0°C at +25°C, while the AD590MH has a tighter calibration error of ±0.5°C at +25°C, reflecting its higher accuracy grade.