AD822AR
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 6939 PCS
- Package
- SOIC-8
- Series
- 선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기
AD822AR과 AD8221BR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The AD822AR and AD8221BR are not drop-in replacements for one another. Although both are precision instrumentation amplifiers, they differ in package footprint, gain programming architecture, and specified performance grades, so substituting one for the other requires board-level redesign and full revalidation rather than a direct swap.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD822AR | AD8221BR | Why it matters |
|---|---|---|---|
| Amplifier Type | General Purpose, Dual Channel | Instrumentation Amplifier, Single Channel | The two parts serve fundamentally different functions; AD822AR is a dual op-amp while AD8221BR is a precision in-amp, so they are not direct substitutes. |
| Number of Channels | 2 | 1 | Channel count determines how many independent signal paths can be processed per package. |
| Input Offset Voltage (Max) | 0.8 mV | 0.025 mV | Lower offset voltage yields higher DC accuracy, critical for precision measurement applications. |
| Gain Bandwidth Product | 1.9 MHz | 825 kHz (G=1) | Bandwidth affects the maximum signal frequency the amplifier can handle with acceptable fidelity. |
| Input Bias Current (Typ) | 2 pA | 0.5 nA | Bias current impacts error in high-impedance source applications; lower is generally better. |
| Supply Voltage Range | ±2.5 V to ±15 V (5 V to 30 V) | ±2.3 V to ±18 V (4.6 V to 36 V) | Supply range determines compatibility with the system power rails and headroom available. |
| CMRR (Min) | 80 dB | 100 dB (G=10) | Common-mode rejection ratio is essential for rejecting noise and interference in differential signal acquisition. |
| Package | 8-Lead SOIC | 8-Lead SOIC | Package compatibility affects PCB footprint and assembly, though both share the same SOIC outline here. |
| Operating Temperature Range | -40°C to +85°C | -40°C to +85°C | Temperature range confirms suitability for industrial and commercial environments. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD822AR | AD8221BR |
|---|---|---|
| Supplier | - | Analog Devices Inc.,Rochester Electronics, LLC |
| Part Status | Obsolete | Obsolete |
| Amplifier Type | General Purpose | Instrumentation |
| Number of Circuits | 2 | 1 |
| Slew Rate | 3V/µs | 2V/µs |
| -3 dB Bandwidth | 1.9 MHz | 825 kHz |
| Current - Input Bias | 2 pA | 200 pA |
| Voltage - Input Offset | 400 µV | 25 µV |
| Supply Current | 1.24mA | 900µA |
| Current - Output / Channel | 20 mA | 18 mA |
| Voltage - Supply Span(Min) | 5 V | 4.6 V |
| Voltage - Supply Span(Max) | 30 V | 36 V |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
| Output Type | Rail-to-Rail | - |
| Gain Bandwidth Product | 1.9 MHz | - |
No, they are not directly interchangeable. The AD822AR is a dual, general-purpose, low-power operational amplifier, while the AD8221BR is a single, high-performance instrumentation amplifier. They differ in function, pinout, package, and key specifications, so a direct drop-in substitution is not possible without redesigning the circuit and validating the new part against the application requirements.
The AD822AR is a dual operational amplifier (two op amps per package) intended for general signal conditioning. The AD8221BR is a monolithic instrumentation amplifier with a single channel, designed for precision differential signal amplification with a gain set by a single external resistor. The AD8221BR provides laser-trimmed gain accuracy and high common-mode rejection, which the general-purpose AD822AR does not specify in the same manner.
The AD822AR is offered in an 8-lead SOIC package (among other options) with the standard dual op-amp pinout. The AD8221BR is offered in an 8-lead SOIC package with an instrumentation amplifier pinout (including gain-setting resistor pins). Although both may use an 8-lead SOIC footprint, the pin functions differ, so the PCB layout and connections are not compatible without modification.
The AD8221BR is the appropriate choice for precision low-level differential signal amplification. As an instrumentation amplifier, it provides high common-mode rejection ratio, low offset voltage, low offset drift, and gain set by a single resistor with tight gain error specifications. The AD822AR, as a general-purpose dual op amp, does not provide the same level of specified instrumentation performance for differential amplification.
Both devices operate from dual supplies, but their specified operating ranges and quiescent currents differ. The AD822AR is specified for operation on supplies up to ±15 V (or single-supply equivalents) with low supply current per amplifier. The AD8221BR is specified for operation on supplies up to ±18 V with a specified quiescent current. Designers must verify the exact supply range and current from the respective manufacturer datasheets for the target operating conditions.
No. The AD8221BR is a single instrumentation amplifier, whereas the AD822AR contains two independent operational amplifiers. Replacing a dual op amp with a single instrumentation amplifier would leave one signal path unamplified and would require a completely different external gain network. The circuit topology, gain configuration, and PCB layout would all need to be redesigned.
The AD822AR is typically used in general-purpose signal conditioning, active filters, buffer amplifiers, and multi-channel low-power amplification where two op amps are needed. The AD8221BR is typically used in precision instrumentation, bridge transducer amplification, medical instrumentation, and data acquisition systems where high common-mode rejection and accurate differential gain are required.
Both parts are available in industrial temperature range versions, but the specific grade suffixes and guaranteed temperature ranges must be confirmed from the manufacturer datasheets. The "AR" and "BR" suffixes denote specific grades and packages; designers should verify the exact operating temperature range and qualification status for the ordered part number rather than assuming equivalence between the two devices.