AD8429BRZ vs AD8422ARZ

AD8429BRZ과 AD8422ARZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD8422ARZ and AD8429BRZ are both precision instrumentation amplifiers in the same SOIC-8 package with identical pinout, making them a viable functional replacement candidate. However, the AD8429BRZ offers lower voltage noise and higher gain bandwidth, while the AD8422ARZ provides wider supply voltage range and lower power consumption. Designers should validate gain-setting resistor values, noise budget, and supply rails before substituting.

Package Type High match
Pin Configuration High match
Supply Voltage Range Validation required
Noise and Bandwidth Validation required

Parts at a glance

Part A

AD8429BRZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
6879 PCS
Package
SOIC-8
Series
선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기
Part B

AD8422ARZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
3872 PCS
Package
SOIC-8
Series
선형 증폭기 - 계측기, 연산 증폭기, 완충 증폭기

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD8422ARZ AD8429BRZ Why it matters
Number of Channels 1 1 Both are single-channel instrumentation amplifiers, so channel count is functionally equivalent.
Gain Bandwidth Product (GBW) 2.2 MHz 15 MHz Higher GBW allows the AD8429BRZ to handle wider signal bandwidths and faster settling, which is critical for high-speed or dynamic measurements.
Input Voltage Noise (1 kHz) 8 nV/√Hz 1 nV/√Hz Lower input voltage noise improves signal-to-noise ratio for low-level signals; the AD8429BRZ is significantly quieter.
Input Offset Voltage (max) 70 µV 50 µV Lower offset voltage reduces DC error at the output, improving accuracy in precision measurement applications.
Input Bias Current (max) 1 nA 150 nA Lower bias current minimizes errors when interfacing with high-impedance sources; the AD8422ARZ is better suited for such sensors.
Common-Mode Rejection Ratio (CMRR, G=100) 120 dB 126 dB Higher CMRR rejects common-mode interference more effectively, improving measurement accuracy in noisy environments.
Supply Voltage Range ±2.3 V to ±18 V ±4 V to ±18 V The AD8422ARZ supports lower supply voltages, enabling use in low-power or battery-operated systems where the AD8429BRZ cannot operate.
Quiescent Supply Current (max) 1.5 mA 6.5 mA Lower quiescent current reduces power consumption, making the AD8422ARZ preferable for power-sensitive designs.
Operating Temperature Range -40 °C to +85 °C -40 °C to +125 °C The wider temperature range of the AD8429BRZ allows operation in harsher environments such as industrial or automotive applications.
Slew Rate 0.8 V/µs 22 V/µs Higher slew rate enables faster response to transient signals and larger full-power bandwidth, important for dynamic measurements.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD8429BRZ AD8422ARZ
Part Status Active Active
Amplifier Type Instrumentation Instrumentation
Number of Circuits 1 1
Slew Rate 22V/µs 0.8V/µs
-3 dB Bandwidth 15 MHz 2.2 MHz
Current - Input Bias 150 nA 500 pA
Voltage - Input Offset 50 µV 60 µV
Supply Current 6.7mA 300µA
Current - Output / Channel 35 mA 20 mA
Voltage - Supply Span(Min) 8 V 4.6 V
Voltage - Supply Span(Max) 36 V 36 V
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Output Type - Rail-to-Rail

Frequently asked questions

What are the key differences between the AD8422ARZ and AD8429BRZ instrumentation amplifiers?

The AD8422ARZ is a high precision, low power, low noise instrumentation amplifier with a gain range of 1 to 1000, typical input offset voltage of 25 µV, and supply current of 300 µA. The AD8429BRZ is an ultralow noise instrumentation amplifier with 1 nV/√Hz input voltage noise, gain range of 1 to 10000, and higher supply current. The AD8429BRZ is optimized for low noise applications, while the AD8422ARZ is optimized for low power and high precision.

Are the AD8422ARZ and AD8429BRZ pin-compatible?

Both devices are offered in 8-lead SOIC packages with the same pinout (gain resistor pins, -IN, +IN, V-, REF, VOUT, V+). However, designers must verify package dimensions and thermal characteristics against the respective datasheets before substituting one for the other on an existing PCB.

Which device has lower input voltage noise, the AD8422ARZ or the AD8429BRZ?

The AD8429BRZ has significantly lower input voltage noise at 1 nV/√Hz typical, compared to the AD8422ARZ which specifies approximately 8 nV/√Hz typical. The AD8429BRZ is therefore preferred for low-level signal amplification where noise floor is critical.

How do the power consumption specifications compare between the AD8422ARZ and AD8429BRZ?

The AD8422ARZ draws a typical supply current of 300 µA, making it suitable for battery-powered and portable instrumentation. The AD8429BRZ draws a higher typical supply current of approximately 4.5 mA, reflecting its ultralow noise architecture. Designs prioritizing power efficiency should favor the AD8422ARZ.

What is the gain range of each device?

The AD8422ARZ supports gains from 1 to 1000 set by a single external resistor. The AD8429BRZ supports gains from 1 to 10000 using a single external gain resistor. The wider gain range of the AD8429BRZ suits applications requiring higher amplification of very small signals.

Which device offers better DC precision for precision measurement applications?

The AD8422ARZ offers typical input offset voltage of 25 µV and low offset drift, along with high CMRR, making it well suited for precision DC measurement. The AD8429BRZ prioritizes low noise over DC offset, with a higher typical input offset voltage. For DC accuracy-critical designs, the AD8422ARZ is generally the better choice.

Can the AD8422ARZ and AD8429BRZ operate from the same supply voltages?

Both devices support dual-supply operation over a wide range. The AD8422ARZ operates from ±2.3 V to ±18 V (or 4.6 V to 36 V single supply), while the AD8429BRZ operates from ±4 V to ±18 V. Designs using supply voltages below ±4 V can use the AD8422ARZ but not the AD8429BRZ.

In which applications would the AD8429BRZ be preferred over the AD8422ARZ?

The AD8429BRZ is preferred in applications requiring ultralow input voltage noise, such as medical instrumentation, seismic sensing, and precision transducer signal conditioning where signal levels are very small. Its 1 nV/√Hz noise and gain up to 10000 make it suitable for extracting low-level signals from high-impedance sources.