AD8495CRMZ vs AD8494ARMZ

AD8495CRMZ과 AD8494ARMZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD8495CRMZ and AD8494ARMZ are both thermocouple amplifier ICs from the same Analog Devices AD849x family, sharing a common functional architecture and SOIC package format. However, they are calibrated for different thermocouple types and differ in temperature range and grade, so the AD8494ARMZ is a functional replacement candidate for the AD8495CRMZ only when the application's thermocouple type and operating range are validated against the target design requirements.

Thermocouple Type Validation required
Temperature Range Validation required
Package Type High match
Grade and Accuracy Validation required

Parts at a glance

Part A

AD8495CRMZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
5995 PCS
Package
MSOP-8
Series
커넥터 - 센서 및 탐지기 커넥터
Part B

AD8494ARMZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
9077 PCS
Package
TSSOP-8
Series
커넥터 - 센서 및 탐지기 커넥터

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD8495CRMZ AD8494ARMZ Why it matters
Sensor Type K-type thermocouple J-type thermocouple Determines which thermocouple alloy the amplifier's cold-junction compensation and gain are calibrated for; using the wrong type causes large temperature errors.
Output Voltage Range 0 V to 5 V (single supply) 0 V to 5 V (single supply) Both are specified for single-supply 0–5 V output, but the internal gain scaling differs by thermocouple type, affecting the usable output span.
Nominal Gain ~122.4 V/V (5 mV/°C) ~122.4 V/V (5 mV/°C) The gain sets the output sensitivity; both target 5 mV/°C, but the cold-junction compensation curve is matched to a different thermocouple type.
Cold-Junction Compensation Optimized for K-type Optimized for J-type The on-chip compensation network must match the thermocouple's Seebeck characteristic; mismatch introduces systematic temperature offset.
Supply Voltage Range 2.7 V to 18 V (single) / ±2.7 V to ±18 V (dual) 2.7 V to 18 V (single) / ±2.7 V to ±18 V (dual) Wide supply range allows flexible system design; both parts share the same supply capability, so this is not a differentiator.
Operating Temperature Range −40 °C to +125 °C −40 °C to +125 °C Industrial temperature range supports harsh environments; identical for both parts.
Package 8-Lead MSOP (RM) 8-Lead MSOP (RM) Same footprint and pinout enable drop-in board compatibility, but electrical compensation differs.
Input Offset Voltage Low offset (precision amplifier) Low offset (precision amplifier) Offset directly translates to temperature measurement error; both are precision-grade, so offset is comparable.
Thermocouple Compatibility K-type only J-type only Functional substitutability requires matching the thermocouple in the system; the two parts are not interchangeable without changing the sensor type.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD8495CRMZ AD8494ARMZ
Supplier - Analog Devices Inc.
Part Status Active Active
Type Thermocouple Amplifier Thermocouple Amplifier
Input Type Differential Differential
Output Type Analog Analog
Supply Current 250 µA 250 µA
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the primary functional differences between the AD8495CRMZ and AD8494ARMZ?

Both are thermocouple amplifiers with cold junction compensation, but they are optimized for different thermocouple types. The AD8495CRMZ is calibrated for Type K thermocouples with a nominal output of 5 mV/°C, while the AD8494ARMZ is calibrated for Type J thermocouples with a nominal output of 5 mV/°C. The AD8495CRMZ is specified over a 0°C to +50°C ambient temperature range, whereas the AD8494ARMZ is specified over a −40°C to +125°C ambient temperature range.

Are the AD8495CRMZ and AD8494ARMZ pin-compatible?

Yes. Both devices are offered in an 8-lead SOIC package with the same pinout, so they are pin-compatible. However, because they are calibrated for different thermocouple types, the surrounding circuit and firmware scaling must be adjusted accordingly.

Can the AD8495CRMZ and AD8494ARMZ be used interchangeably in an existing design?

Not directly without design validation. The AD8495CRMZ is calibrated for Type K thermocouples and the AD8494ARMZ for Type J thermocouples, so the measured temperature-to-voltage transfer function differs. Substitution requires verifying the thermocouple type, output scaling, and the ambient temperature range against the datasheet specifications for each part.

What supply voltage range do the AD8495CRMZ and AD8494ARMZ require?

Both devices operate from a single supply of 2.7 V to 18 V, or from dual supplies of ±2.7 V to ±18 V, as specified in the manufacturer datasheet. The actual usable range depends on the required output swing and thermocouple input range.

How does the operating temperature range differ between the two parts?

The AD8495CRMZ is specified for operation over a 0°C to +50°C ambient temperature range, while the AD8494ARMZ is specified over a −40°C to +125°C ambient temperature range. Designs requiring extended ambient operation should account for this difference.

Do both devices include cold junction compensation?

Yes. Both the AD8495CRMZ and AD8494ARMZ integrate cold junction compensation circuitry, eliminating the need for an external temperature sensor and compensation network. The compensation is calibrated for the respective thermocouple type of each device.

What is the output voltage sensitivity of each device?

Both the AD8495CRMZ and AD8494ARMZ provide a nominal output sensitivity of 5 mV/°C, referenced to the respective thermocouple type. The AD8495CRMZ is calibrated for Type K thermocouples and the AD8494ARMZ for Type J thermocouples.