AD9513BCPZ vs AD9517-2BCPZ

AD9513BCPZ과 AD9517-2BCPZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The AD9513BCPZ and AD9517-2BCPZ are not drop-in replacements for one another. Although both are Analog Devices clock distribution ICs in a 32-lead LFCSP package, they differ fundamentally in output architecture, channel count, and internal PLL integration, so the AD9517-2BCPZ cannot be substituted directly for the AD9513BCPZ without a full board and system-level redesign.

Different output type Different channel count Integrated PLL vs PLL-less Different divider architecture

Parts at a glance

Part A

AD9513BCPZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
6808 PCS
Package
LFCSP-32
Series
시계 타이밍 - 시계 버퍼, 드라이브
Part B

AD9517-2BCPZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
4856 PCS
Package
VFQFN-48
Series
클럭 타이밍 - 클럭 발생기, PLL, 주파수 합성기

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD9513BCPZ AD9517-2BCPZ Why it matters
Number of Outputs 3 (LVPECL, LVDS, CMOS selectable) 12 (LVPECL, LVDS, CMOS) Output count determines how many clock destinations can be driven; a 3-output device cannot replace a 12-output device in multi-load systems.
Input Frequency Range Up to 1.6 GHz Up to 2.4 GHz Maximum input frequency limits the reference clock rates the device can accept, affecting compatibility with high-speed system clocks.
Output Frequency Range Up to 1.6 GHz Up to 2.4 GHz Output frequency ceiling determines whether the part can generate the required clock rates for the target application.
On-Chip VCO No Yes (2.2 GHz to 2.4 GHz) An integrated VCO allows the device to generate clocks without an external oscillator, simplifying design and reducing board space.
On-Chip Dividers Yes (1 to 32) Yes (1 to 32, plus 2 to 32) Divider flexibility affects the range of output frequencies that can be derived from a single input clock.
Package 32-Lead LFCSP (5 mm x 5 mm) 48-Lead LFCSP (7 mm x 7 mm) Package footprint and pin count affect PCB layout and cannot be directly substituted without board redesign.
Supply Voltage 3.3 V 3.3 V Supply voltage compatibility ensures the device operates within the same power rail as the rest of the system.
Output Logic Types LVPECL, LVDS, CMOS LVPECL, LVDS, CMOS Supported logic standards determine which downstream receivers can be interfaced directly.
Additive Jitter ~0.2 ps RMS (typical) ~0.2 ps RMS (typical) Low additive jitter is critical for maintaining signal integrity in high-speed data converters and communication systems.
Operating Temperature Range -40°C to +85°C -40°C to +85°C Industrial temperature range ensures reliable operation across harsh environments.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD9513BCPZ AD9517-2BCPZ
Supplier - Rochester Electronics, LLC
Part Status Active Obsolete
Type Fanout Buffer (Distribution), Divider Clock Generator, Fanout Distribution
PLL - Yes
Input Clock CMOS, LVDS, LVPECL
Output CMOS, LVDS CMOS, LVDS, LVPECL
Ratio - Input: Output 1:3 1:12
Differential - Input: Output Yes/Yes Yes/Yes
Frequency - Max 800 MHz 2.33GHz
Divider / Multiplier - Yes/No
Voltage - Supply 3.135V ~ 3.465V 3.135V ~ 3.465V
Mounting Type Surface Mount Surface Mount
Number of Circuits 1 -
Operating Temperature -40°C ~ 85°C -

Frequently asked questions

What are the primary functional differences between the AD9513BCPZ and the AD9517-2BCPZ?

The AD9513BCPZ is a 3-output clock distribution IC with a 1.6 GHz maximum input frequency, integrated integer dividers, and adjustable delay. The AD9517-2BCPZ is a more highly integrated clock generator and distribution IC featuring an on-chip VCO (2.2 GHz to 2.4 GHz for the -2 version), a PLL with programmable dividers, and up to 8 outputs (LVPECL, LVDS, or CMOS). The AD9517-2BCPZ includes a PLL and VCO, whereas the AD9513BCPZ is a fanout buffer/distributor without an integrated PLL or VCO.

Are the AD9513BCPZ and AD9517-2BCPZ pin-to-pin or package compatible?

No. Both devices are offered in a 32-lead LFCSP (5 mm × 5 mm) package, but their pin functions and internal architectures differ significantly. The AD9517-2BCPZ integrates a PLL, VCO, and additional output channels, so the pinout is not interchangeable. A direct PCB drop-in replacement is not possible without layout and schematic changes.

How do the output configurations of the AD9513BCPZ and AD9517-2BCPZ compare?

The AD9513BCPZ provides three outputs: one LVPECL output and two LVDS outputs, each with programmable divider and delay. The AD9517-2BCPZ provides up to eight outputs configurable as LVPECL, LVDS, or CMOS, with independent programmable dividers and delay blocks. The AD9517-2BCPZ therefore offers greater output count and flexibility for multi-clock-domain systems.

Does the AD9517-2BCPZ include a PLL and VCO that the AD9513BCPZ lacks?

Yes. The AD9517-2BCPZ integrates an on-chip PLL with a programmable reference divider, phase-frequency detector, charge pump, and an integrated VCO operating from 2.2 GHz to 2.4 GHz (for the -2 grade). The AD9513BCPZ does not contain a PLL or VCO; it is a clock distribution/fanout device that requires an external clock source.

What are the maximum input frequencies for the AD9513BCPZ and AD9517-2BCPZ?

The AD9513BCPZ supports a maximum input frequency of 1.6 GHz. The AD9517-2BCPZ, when using its integrated VCO, generates output frequencies derived from the 2.2 GHz to 2.4 GHz VCO range, and its external clock input path supports frequencies per the datasheet specifications. Designers should consult the respective datasheets for exact input frequency limits under specific configurations.

Can the AD9513BCPZ be used as a substitute for the AD9517-2BCPZ in an existing design?

No, not as a direct substitute. The AD9517-2BCPZ provides an integrated PLL/VCO and up to eight outputs, while the AD9513BCPZ provides only three outputs and no PLL/VCO. A design requiring the AD9517-2BCPZ's clock generation or higher output count cannot be satisfied by the AD9513BCPZ without significant architectural changes, including an external clock source and PLL circuitry.

What are the typical applications for each device?

The AD9513BCPZ is typically used for clock distribution and fanout in applications such as data converters, networking, and instrumentation where a low-jitter, multi-output buffer is needed without integrated clock generation. The AD9517-2BCPZ is used in applications requiring integrated clock generation and distribution, such as wireless base stations, broadband infrastructure, and high-speed data acquisition systems where an on-chip PLL/VCO and multiple programmable outputs simplify the clock tree.