ADM3050EBRWZ-RL
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 4499 PCS
- Package
- SOIC-16
- Series
- 인터페이스 - 드라이브, 수신기, 트랜시버
ADM3050EBRWZ-RL과 ADM3076EARZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADM3076EARZ and ADM3050EBRWZ-RL are not drop-in replacements for one another. Although both are Analog Devices RS-485 transceivers, they differ in isolation, data rate, supply voltage, and package, so the ADM3050EBRWZ-RL cannot directly substitute the ADM3076EARZ without design validation.
아날로그 디바이스(주)
아날로그 디바이스(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADM3076EARZ | ADM3050EBRWZ-RL | Why it matters |
|---|---|---|---|
| Function / Protocol | RS-485/RS-422 transceiver | Isolated CAN transceiver (CAN FD capable) | These devices serve entirely different bus protocols (RS-485 vs CAN), so they are not functionally interchangeable in a given network. |
| Isolation | Non-isolated | Galvanically isolated (5 kV rms) | Isolation determines safety, ground-loop immunity, and suitability for harsh or high-voltage environments; the isolated part cannot be replaced by a non-isolated one without redesign. |
| Data Rate | Up to 16 Mbps | Up to 12 Mbps (CAN FD) | Maximum data rate must match the bus timing requirements; the two parts support different throughput ceilings. |
| Supply Voltage | 3.0 V to 3.6 V (single 3.3 V supply) | 5 V (VCC) with integrated isolated DC-DC | Supply rail compatibility affects board-level power design; the isolated CAN part requires a 5 V primary supply and generates its own isolated secondary rail. |
| Duplex / Channel Configuration | Full-duplex RS-485/RS-422 | Half-duplex CAN (single differential pair) | Bus topology and wiring differ fundamentally between full-duplex RS-485 and half-duplex CAN, preventing direct substitution. |
| Package | 8-lead SOIC (R-8) | 16-lead SOIC (RW-16) | Footprint and pin count differ, so the PCB layout cannot be shared between the two parts. |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +105 °C | The wider temperature range of the CAN part suits more demanding industrial environments; substitution must respect the narrower range of the RS-485 part. |
| Number of Transceivers per Package | 1 driver / 1 receiver | 1 CAN transceiver with integrated isolator and DC-DC | The isolated CAN device integrates isolation and power conversion, changing the external component count and system architecture. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADM3050EBRWZ-RL | ADM3076EARZ |
|---|---|---|
| Series | iCoupler® | - |
| Part Status | Active | Active |
| Type | Transceiver, Isolated | Transceiver |
| Protocol | CAN | RS422, RS485 |
| Number of Drivers/Receivers | 1/1 | 1/1 |
| Data Rate | 12Mbps | 16Mbps |
| Voltage - Supply | 0.5V ~ 6V | 3V ~ 3.6V |
| Operating Temperature | -40°C ~ 125°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
| Duplex | - | Full |
| Receiver Hysteresis | - | 100 mV |
The ADM3076EARZ is a 3.3 V, ±15 kV ESD protected, half-duplex RS-485/RS-422 transceiver in an 8-lead SOIC package. The ADM3050EBRWZ-RL is a 5 kV rms isolated CAN FD transceiver in a 16-lead SOIC_W package. The ADM3076EARZ provides non-isolated RS-485/RS-422 communication, while the ADM3050EBRWZ-RL provides galvanically isolated CAN FD communication.
No. The ADM3076EARZ uses an 8-lead SOIC package, while the ADM3050EBRWZ-RL uses a 16-lead SOIC_W package. The pin counts, pin functions, and package footprints differ, so they are not drop-in replacements for each other.
No. The ADM3076EARZ supports RS-485 and RS-422 differential signaling. The ADM3050EBRWZ-RL supports CAN FD (Flexible Data Rate) communication. They are intended for different bus protocols and cannot interoperate on the same bus without appropriate protocol conversion.
The ADM3076EARZ operates from a single 3.3 V supply. The ADM3050EBRWZ-RL operates from a 5 V supply on the logic side and an isolated supply on the bus side, as required by its integrated isolated DC-to-DC converter architecture. Designers should confirm exact supply rail requirements in the respective manufacturer datasheets.
Yes. The ADM3050EBRWZ-RL is an isolated CAN FD transceiver rated for 5 kV rms isolation, suitable for applications requiring galvanic isolation between nodes. The ADM3076EARZ is a non-isolated RS-485/RS-422 transceiver and does not provide galvanic isolation.
The ADM3076EARZ is specified with ±15 kV ESD protection on the RS-485/RS-422 bus pins, per the manufacturer datasheet. This protection applies to the non-isolated bus interface and should not be confused with galvanic isolation.
They can coexist in the same system only if the system includes separate RS-485/RS-422 and isolated CAN FD buses, or appropriate protocol bridging. Because they implement different protocols and one is isolated while the other is not, they cannot directly share the same bus segment or serve as substitutes for one another.