ADM3050EBRWZ-RL vs ADM3076EARZ

ADM3050EBRWZ-RL과 ADM3076EARZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADM3076EARZ and ADM3050EBRWZ-RL are not drop-in replacements for one another. Although both are Analog Devices RS-485 transceivers, they differ in isolation, data rate, supply voltage, and package, so the ADM3050EBRWZ-RL cannot directly substitute the ADM3076EARZ without design validation.

Different isolation Different data rate Different supply voltage Different package

Parts at a glance

Part A

ADM3050EBRWZ-RL

아날로그 디바이스(주)

Lifecycle
Active
Stock
4499 PCS
Package
SOIC-16
Series
인터페이스 - 드라이브, 수신기, 트랜시버
Part B

ADM3076EARZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
5876 PCS
Package
SOIC-14
Series
인터페이스 - 드라이브, 수신기, 트랜시버

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADM3076EARZ ADM3050EBRWZ-RL Why it matters
Function / Protocol RS-485/RS-422 transceiver Isolated CAN transceiver (CAN FD capable) These devices serve entirely different bus protocols (RS-485 vs CAN), so they are not functionally interchangeable in a given network.
Isolation Non-isolated Galvanically isolated (5 kV rms) Isolation determines safety, ground-loop immunity, and suitability for harsh or high-voltage environments; the isolated part cannot be replaced by a non-isolated one without redesign.
Data Rate Up to 16 Mbps Up to 12 Mbps (CAN FD) Maximum data rate must match the bus timing requirements; the two parts support different throughput ceilings.
Supply Voltage 3.0 V to 3.6 V (single 3.3 V supply) 5 V (VCC) with integrated isolated DC-DC Supply rail compatibility affects board-level power design; the isolated CAN part requires a 5 V primary supply and generates its own isolated secondary rail.
Duplex / Channel Configuration Full-duplex RS-485/RS-422 Half-duplex CAN (single differential pair) Bus topology and wiring differ fundamentally between full-duplex RS-485 and half-duplex CAN, preventing direct substitution.
Package 8-lead SOIC (R-8) 16-lead SOIC (RW-16) Footprint and pin count differ, so the PCB layout cannot be shared between the two parts.
Operating Temperature Range -40 °C to +85 °C -40 °C to +105 °C The wider temperature range of the CAN part suits more demanding industrial environments; substitution must respect the narrower range of the RS-485 part.
Number of Transceivers per Package 1 driver / 1 receiver 1 CAN transceiver with integrated isolator and DC-DC The isolated CAN device integrates isolation and power conversion, changing the external component count and system architecture.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADM3050EBRWZ-RL ADM3076EARZ
Series iCoupler® -
Part Status Active Active
Type Transceiver, Isolated Transceiver
Protocol CAN RS422, RS485
Number of Drivers/Receivers 1/1 1/1
Data Rate 12Mbps 16Mbps
Voltage - Supply 0.5V ~ 6V 3V ~ 3.6V
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C
Mounting Type Surface Mount Surface Mount
Duplex - Full
Receiver Hysteresis - 100 mV

Frequently asked questions

What are the primary functional differences between the ADM3076EARZ and the ADM3050EBRWZ-RL?

The ADM3076EARZ is a 3.3 V, ±15 kV ESD protected, half-duplex RS-485/RS-422 transceiver in an 8-lead SOIC package. The ADM3050EBRWZ-RL is a 5 kV rms isolated CAN FD transceiver in a 16-lead SOIC_W package. The ADM3076EARZ provides non-isolated RS-485/RS-422 communication, while the ADM3050EBRWZ-RL provides galvanically isolated CAN FD communication.

Are the ADM3076EARZ and ADM3050EBRWZ-RL pin-to-pin or package compatible?

No. The ADM3076EARZ uses an 8-lead SOIC package, while the ADM3050EBRWZ-RL uses a 16-lead SOIC_W package. The pin counts, pin functions, and package footprints differ, so they are not drop-in replacements for each other.

Do the ADM3076EARZ and ADM3050EBRWZ-RL support the same communication protocol?

No. The ADM3076EARZ supports RS-485 and RS-422 differential signaling. The ADM3050EBRWZ-RL supports CAN FD (Flexible Data Rate) communication. They are intended for different bus protocols and cannot interoperate on the same bus without appropriate protocol conversion.

What are the supply voltage requirements for each device?

The ADM3076EARZ operates from a single 3.3 V supply. The ADM3050EBRWZ-RL operates from a 5 V supply on the logic side and an isolated supply on the bus side, as required by its integrated isolated DC-to-DC converter architecture. Designers should confirm exact supply rail requirements in the respective manufacturer datasheets.

Does the ADM3050EBRWZ-RL provide galvanic isolation while the ADM3076EARZ does not?

Yes. The ADM3050EBRWZ-RL is an isolated CAN FD transceiver rated for 5 kV rms isolation, suitable for applications requiring galvanic isolation between nodes. The ADM3076EARZ is a non-isolated RS-485/RS-422 transceiver and does not provide galvanic isolation.

What ESD protection levels are specified for the ADM3076EARZ?

The ADM3076EARZ is specified with ±15 kV ESD protection on the RS-485/RS-422 bus pins, per the manufacturer datasheet. This protection applies to the non-isolated bus interface and should not be confused with galvanic isolation.

Can the ADM3076EARZ and ADM3050EBRWZ-RL be used in the same system?

They can coexist in the same system only if the system includes separate RS-485/RS-422 and isolated CAN FD buses, or appropriate protocol bridging. Because they implement different protocols and one is isolated while the other is not, they cannot directly share the same bus segment or serve as substitutes for one another.