ADR420BRZ
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 6197 PCS
- Package
- SOIC-8
- Series
- PMIC - 전압 참조
ADR420BRZ과 ADR420AR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADR420BRZ and ADR420AR are functionally compatible voltage reference ICs sharing the same 2.048 V output, series topology, and SOIC-8 footprint, making the ADR420AR a viable drop-in candidate for the ADR420BRZ in most designs. The primary distinction is grade-level accuracy: the BRZ offers tighter initial tolerance and lower temperature coefficient, so applications with stringent precision budgets should validate the relaxed specifications of the AR before substitution.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADR420BRZ | ADR420AR | Why it matters |
|---|---|---|---|
| Initial Accuracy (Vout) | ±1 mV (max, ±0.05%) | ±2 mV (max, ±0.1%) | Tighter initial tolerance reduces system calibration effort and improves absolute output accuracy. |
| Temperature Coefficient | 3 ppm/°C (max, B grade) | 10 ppm/°C (max, A grade) | Lower tempco keeps the reference stable over temperature, critical for precision measurement and industrial applications. |
| Grade / Accuracy Class | B grade (high precision) | A grade (standard precision) | Grade determines guaranteed limits on accuracy and drift; B grade is a higher-performance bin than A grade. |
| Output Voltage | 2.048 V | 2.048 V | Both provide the same nominal reference voltage, so the output range is directly compatible. |
| Package | 8-Lead SOIC (RZ) | 8-Lead SOIC (R) | Identical package footprint allows drop-in board replacement without layout changes. |
| Supply Voltage Range | 4.0 V to 18 V | 4.0 V to 18 V | Same operating supply window ensures compatibility with the same system power rails. |
| Operating Temperature Range | −40 °C to +125 °C | −40 °C to +125 °C | Matching temperature ratings confirm both parts suit the same environmental conditions. |
| Output Current Capability | ±10 mA (source/sink) | ±10 mA (source/sink) | Same drive capability means both can support comparable load conditions in the target circuit. |
| Low-Frequency Noise | 1.75 µV p-p (0.1 Hz to 10 Hz, typ) | 1.75 µV p-p (0.1 Hz to 10 Hz, typ) | Equivalent noise performance preserves signal integrity in precision analog front ends. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADR420BRZ | ADR420AR |
|---|---|---|
| Series | XFET® | XFET® |
| Part Status | Active | Obsolete |
| Mounting Type | Surface Mount | Surface Mount |
| Reference Type | Series | - |
| Output Type | Fixed | - |
| Voltage - Output (Min/Fixed) | 2.048V | - |
| Current - Output | 10 mA | - |
| Tolerance | ±0.05% | - |
| Temperature Coefficient | 3ppm/°C | - |
| Noise - 01 Hzto10 Hz | 1.75µVp-p | - |
| Voltage - Input | 4V ~ 18V | - |
| Supply Current | 600µA | - |
| Operating Temperature | -40°C ~ 125°C (TA) | - |
The primary difference is the initial accuracy grade. The ADR420BRZ (B grade) offers a tighter initial output voltage tolerance of ±0.04% maximum, while the ADR420AR (A grade) specifies ±0.1% maximum. Both are 2.048 V precision voltage references in an 8-lead SOIC package.
Yes. Both devices are offered in the same 8-lead SOIC (R-8) package with identical pin functions, so they are pin-compatible and share the same PCB land pattern.
Both devices provide a fixed 2.048 V output. The ADR420BRZ specifies ±0.04% maximum initial accuracy, and the ADR420AR specifies ±0.1% maximum initial accuracy at 25°C.
Yes. The ADR420BRZ (B grade) is specified with a maximum temperature coefficient of 3 ppm/°C, while the ADR420AR (A grade) is specified with a maximum temperature coefficient of 10 ppm/°C over the operating temperature range.
They are pin-compatible, but the ADR420AR has wider initial accuracy (±0.1% vs ±0.04%) and temperature coefficient (10 ppm/°C vs 3 ppm/°C) tolerances. A replacement is acceptable only if the looser specifications still meet the design's error budget; otherwise the B grade should be retained.
Both grades are specified over the extended industrial temperature range of −40°C to +125°C, with their respective accuracy and temperature coefficient limits applying across that range.
Both are members of the ADR420 family and share the same typical long-term drift and low-frequency noise characteristics. The graded differences between the B and A versions are confined to initial accuracy and temperature coefficient, so design calculations for drift and noise can use the same family data for either grade.