ADS1198CPAG vs ADS1196CPAG

ADS1198CPAG과 ADS1196CPAG에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The ADS1196CPAG is a functional replacement candidate for the ADS1198CPAG, sharing the same TQFP-64 package, 16-bit delta-sigma ADC architecture, and identical supply and temperature ranges, with the primary distinction being the reduced channel count (6 vs 8) and correspondingly lower power consumption. Designers must confirm that six channels satisfy the application's signal acquisition requirements before substituting.

Channel Count Validation required
Package Type High match
Resolution and ADC Architecture High match
Supply Voltage and Operating Temperature High match

Parts at a glance

Part A

ADS1198CPAG

텍사스 인스트루먼트(주)

Lifecycle
Active
Stock
3254 PCS
Package
TQFP-64
Series
데이터 수집 - 아날로그 프런트엔드(AFE)
Part B

ADS1196CPAG

텍사스 인스트루먼트(주)

Lifecycle
Active
Stock
3634 PCS
Package
TQFP-64
Series
데이터 수집 - 아날로그 프런트엔드(AFE)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1198CPAG ADS1196CPAG Why it matters
Number of input channels 8 6 Determines how many simultaneous biopotential/ECG signals can be acquired; a direct functional substitutability constraint.
Resolution 16 bit 16 bit Sets the amplitude precision of the ADC; identical resolution means comparable signal fidelity.
Data rate (max) 8 kSPS 8 kSPS Defines the maximum sampling throughput available for each channel; affects bandwidth and timing compatibility.
Supply voltage (analog/digital) 2.7 V to 5.25 V 2.7 V to 5.25 V Must match the system power rail; identical range allows drop-in power compatibility.
Interface SPI SPI Determines host communication protocol; identical SPI interface supports the same firmware/driver.
Package 64-TQFP 64-TQFP Same package and pinout enable PCB footprint compatibility for substitution.
Integrated features PGA, internal reference, lead-off detection, respiration PGA, internal reference, lead-off detection, respiration On-chip signal conditioning and diagnostics reduce external components; matching feature sets preserve system architecture.
Input-referred noise Lower (8-channel variant) Comparable per-channel noise Noise performance affects ECG signal quality; channel count differences can influence overall noise and crosstalk behavior.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1198CPAG ADS1196CPAG
Supplier - Rochester Electronics, LLC,Texas Instruments
Part Status Active Active
Number of Bits 16 16
Number of Channels 8 6
Power (Watts) 8.2 mW 6.9 mW
Voltage - Supply, Analog 2.7V ~ 5.25V 2.7V ~ 5.25V
Voltage - Supply, Digital 1.65V ~ 3.6V 1.65V ~ 3.6V
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What is the primary difference between the ADS1198CPAG and ADS1196CPAG?

The ADS1198CPAG is an 8-channel, 16-bit delta-sigma analog front-end (AFE) for biopotential measurements, while the ADS1196CPAG is a 6-channel, 16-bit device in the same family. Both integrate a programmable gain amplifier, internal reference, oscillator, and SPI-compatible interface in a TQFP-64 package, but the ADS1198 provides two additional input channels.

Are the ADS1198CPAG and ADS1196CPAG pin-compatible?

Both devices are offered in the same 64-pin TQFP (PAG) package and share the same pinout family, but the ADS1196CPAG does not populate all channel inputs that the ADS1198CPAG uses. Designers should verify unused channel pins against the respective datasheets before substituting one for the other on an existing PCB.

Do both devices support the same data rate and resolution?

Yes. Both the ADS1198CPAG and ADS1196CPAG are 16-bit delta-sigma converters with programmable data rates from 250 SPS to 8 kSPS, and both include the same digital decimation filter and SPI interface, so resolution and throughput specifications are identical across the two parts.

Can the ADS1196CPAG be used as a drop-in replacement for the ADS1198CPAG?

Not directly. Although the package and core AFE architecture are shared, the ADS1196CPAG provides only 6 input channels versus 8 on the ADS1198CPAG. Any design requiring all eight channels must retain the ADS1198CPAG; substitution is only valid where the two unused channels are not needed and the pin configuration is confirmed against the datasheet.

What applications are these AFEs intended for?

Both the ADS1198CPAG and ADS1196CPAG are designed for biopotential signal acquisition, including ECG, EEG, and EMG systems, as well as patient monitoring and portable medical instrumentation, where their integrated PGA, reference, and lead-off detection reduce external component count.

Do both parts share the same supply voltage and interface requirements?

Yes. Both devices operate from an analog supply of 2.7 V to 5.25 V and a digital supply of 1.8 V to 3.6 V, and both communicate over a standard SPI-compatible serial interface, so the electrical and interface requirements are consistent between the ADS1198CPAG and ADS1196CPAG.