ADS1204IRHBR
텍사스 인스트루먼트(주)
- Lifecycle
- Active
- Stock
- 6898 PCS
- Package
- VQFN-32
- Series
- 데이터 수집 - ADC DAC- 전용
ADS1204IRHBR과 ADS1287IRHFR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADS1204IRHBR and ADS1287IRHFR are not functionally interchangeable. They differ in resolution, architecture, channel count, and package, so the ADS1287IRHFR cannot directly replace the ADS1204IRHBR without a full redesign and validation of the signal chain.
텍사스 인스트루먼트(주)
텍사스 인스트루먼트(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1204IRHBR | ADS1287IRHFR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 16 | 24 | Higher resolution enables finer signal detail and lower quantization noise, which is critical for precision measurement applications. |
| Architecture | Delta-sigma modulator | Delta-sigma ADC | A modulator outputs a bitstream requiring external filtering, while a full ADC integrates the digital filter, affecting system complexity and interface design. |
| Number of input channels | 4 | 1 | Channel count determines how many independent signals can be measured simultaneously, directly impacting multi-sensor system design. |
| Output interface | Serial bitstream (modulator output) | SPI (serial digital) | The output format dictates the required host interface and whether external digital filtering or decoding logic is needed. |
| Supply voltage | 5 V (analog and digital) | 3.3 V (analog and digital) | Supply voltage compatibility affects power rail design and whether level shifting is required when interfacing with the host system. |
| Package | VQFN-32 (5x5 mm) | VQFN-40 (6x6 mm) | Package footprint and pin count affect PCB layout, thermal performance, and mechanical fit, which are critical for drop-in substitutability. |
| Operating temperature range | -40 to +85 °C | -40 to +125 °C | A wider temperature range supports use in harsher environments and provides greater thermal margin in industrial applications. |
| Input type | Differential | Differential | Differential inputs improve common-mode noise rejection; matching input topology is essential for signal-chain compatibility. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1204IRHBR | ADS1287IRHFR |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | - | 24 |
| Sampling Rate(Per Second) | 40k | 1k |
| Number of Inputs | - | 1 |
| Input Type | - | Differential |
| Data Interface | Parallel | SPI |
| Configuration | - | MUX-PGA-ADC |
| Ratio - S / H: ADC | - | 0:1 |
| Number of A/D Converters | - | 1 |
| Architecture | - | Sigma-Delta |
| Reference Type | - | External |
| Voltage - Supply, Analog | - | 4.75V ~ 5.25V |
| Voltage - Supply, Digital | - | 2.25V ~ 3.6V |
| Features | - | PGA |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
| Type | Modulator | - |
| Number of Channels | 4 | - |
| Resolution(Bits) | 16 b | - |
| Voltage Supply Source | Analog and Digital | - |
| Voltage - Supply | 2.7V ~ 5.5V | - |
| Mounting Type | Surface Mount | - |
The ADS1204IRHBR is a four-channel, 16-bit delta-sigma modulator with a maximum data rate of 40 kSPS per channel, designed for isolated current and voltage sensing. The ADS1287IRHFR is a single-channel, 32-bit delta-sigma ADC with a maximum data rate of 4 kSPS, optimized for high-resolution seismic and energy exploration applications. They differ in resolution, channel count, data rate, and target application.
No. The ADS1204IRHBR is supplied in a 32-pin VQFN (RHB) package, while the ADS1287IRHFR is supplied in a 24-pin VQFN (RHF) package. The pin counts, package sizes, and pin functions differ, so they are not drop-in replacements for each other.
No. The ADS1204IRHBR provides a serial delta-sigma modulator output stream per channel and requires an external digital filter or modulator demodulator; its clock is supplied via the MCLK pin. The ADS1287IRHFR integrates a full ADC with on-chip digital filtering and provides a SPI-compatible serial interface for configuration and data readout. The interface protocols and system clocking requirements are not interchangeable.
The ADS1204IRHBR is better suited because it integrates four independent delta-sigma modulator channels in one package, allowing simultaneous multi-phase or multi-channel current and voltage sensing with a single device. The ADS1287IRHFR is a single-channel ADC and would require multiple devices for multi-channel sensing.
The ADS1287IRHFR offers higher resolution at 32 bits and is specified for low-noise, high-resolution seismic and energy exploration data acquisition. The ADS1204IRHBR provides 16-bit modulator resolution and is intended for isolated current and voltage sensing rather than high-resolution seismic measurement.
No. The ADS1204IRHBR operates from a 5 V analog supply with a separate digital supply, while the ADS1287IRHFR operates from a 5 V analog supply and a 1.8 V to 3.3 V digital supply. The supply rails and sequencing requirements differ and must be verified against each device's datasheet before design.
No. The ADS1204IRHBR is a 16-bit, four-channel modulator without an integrated digital filter or SPI configuration interface, whereas the ADS1287IRHFR is a 32-bit, single-channel ADC with integrated digital filtering and a SPI interface. Resolution, channel count, package, and interface differences prevent a direct substitution without redesign.