ADS1230IPW
텍사스 인스트루먼트(주)
- Lifecycle
- Active
- Stock
- 2859 PCS
- Package
- TSSOP-16
- Series
- 데이터 수집 - 아날로그 변환기(ADC)
ADS1230IPW과 ADS1222IPWRG4에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADS1230IPW and ADS1222IPWRG4 are not drop-in replacements for each other. Although both are 24-bit delta-sigma analog-to-digital converters in TSSOP packages, they differ in resolution architecture, input channel configuration, interface timing, and reference/supply requirements, so a direct board-level substitution is not feasible without design validation.
텍사스 인스트루먼트(주)
텍사스 인스트루먼트(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1230IPW | ADS1222IPWRG4 | Why it matters |
|---|---|---|---|
| Resolution (bits) | 20 | 24 | Higher resolution allows detection of smaller signal changes, which is critical for precision measurement applications. |
| Number of input channels | 1 (differential) | 2 (differential) | More channels allow multiple sensors to be interfaced without external multiplexing, affecting system complexity and cost. |
| Interface type | SPI (2-wire, read-only) | SPI (4-wire) | Interface compatibility determines whether the part can drop into an existing digital bus design without firmware or wiring changes. |
| Data rate (SPS) | 10 or 80 | Up to 105 | Data rate affects measurement throughput and noise trade-off; different rates may not meet timing requirements of the target system. |
| Supply voltage range | 2.7 V to 5.3 V | 2.7 V to 5.5 V | Supply range must cover the system rail; a narrower range may limit operation at higher supply voltages. |
| Package | 16-TSSOP | 16-TSSOP | Package footprint and pinout determine PCB layout compatibility for direct substitution. |
| Internal PGA gain | 128 (fixed) | 1 to 128 (programmable) | Programmable gain allows adaptation to different sensor signal amplitudes, while a fixed gain restricts input range flexibility. |
| Operating temperature range | -40 °C to +85 °C | -40 °C to +105 °C | Wider temperature range supports use in harsher environments and provides margin in industrial applications. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1230IPW | ADS1222IPWRG4 |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Discontinued at Digi-Key |
| Number of Bits | 20 | 24 |
| Sampling Rate(Per Second) | 80 | 240 |
| Number of Inputs | 1 | 2 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | PGA-ADC | MUX-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 2.7V ~ 5.3V | 2.7V ~ 5.5V |
| Voltage - Supply, Digital | 2.7V ~ 5.3V | 2.7V ~ 5.5V |
| Features | PGA | Temperature Sensor |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
The ADS1230IPW is a 20-bit delta-sigma analog-to-digital converter designed specifically for weigh scales and bridge sensors, featuring a low-noise PGA with gains of 1, 2, 64, and 128. The ADS1222IPWRG4 is a 24-bit delta-sigma ADC with a flexible input multiplexer, internal oscillator, and programmable gain amplifier, intended for general-purpose precision measurement applications. The ADS1230 integrates a dedicated bridge excitation switch and is optimized for direct thermocouple and load-cell interfacing, while the ADS1222 offers higher resolution and a wider input multiplexer configuration.
No. The ADS1230IPW is supplied in a 16-pin TSSOP package, while the ADS1222IPWRG4 is supplied in a 16-pin TSSOP package as well, but the pin functions and internal signal routing differ between the two devices. The ADS1230IPW pinout is dedicated to bridge sensor applications with fixed PGA settings and a specific clock/data interface, whereas the ADS1222IPWRG4 assigns pins to a multiplexer, external reference inputs, and a different digital interface. Direct PCB substitution is not possible without layout and firmware changes.
The ADS1222IPWRG4 provides 24-bit resolution, while the ADS1230IPW provides 20-bit resolution. The ADS1230IPW achieves approximately 19.5 effective bits at a gain of 128 with a 10 SPS data rate, whereas the ADS1222IPWRG4 delivers up to 24 bits with programmable data rates and gain settings. The higher nominal resolution of the ADS1222IPWRG4 makes it suitable for applications requiring finer measurement granularity, while the ADS1230IPW is optimized for low-noise bridge measurements at lower resolution.
The ADS1230IPW supports selectable data rates of 10 SPS and 80 SPS. The ADS1222IPWRG4 supports programmable data rates up to 2 kSPS depending on configuration and filter settings. The ADS1230IPW is intentionally limited to low data rates to achieve low noise for weigh-scale applications, while the ADS1222IPWRG4 offers higher throughput for general-purpose precision sensing.
Yes. The ADS1230IPW includes an internal oscillator that provides the clock for the modulator and digital filter, eliminating the need for an external clock source in most applications. The ADS1222IPWRG4 also integrates an internal oscillator, with the option to use an external clock if required by the system design. Both devices can operate without an external crystal or oscillator in typical configurations.
The ADS1230IPW operates from a single analog supply of 2.7 V to 5.3 V and a digital supply of 2.7 V to 5.3 V, with typical power consumption of approximately 1.5 mW at 3 V in normal mode and significantly lower in power-down mode. The ADS1222IPWRG4 operates from a single supply of 2.7 V to 5.5 V, with typical power consumption around 1.2 mW at 3 V depending on data rate and configuration. Both devices are suitable for low-power portable instrumentation, though exact consumption depends on selected gain, data rate, and supply voltage.
The ADS1230IPW is specifically designed for weigh-scale and bridge-sensor applications. It integrates a low-noise PGA with gain settings of 1, 2, 64, and 128, a dedicated bridge excitation switch, and a fixed 10 SPS or 80 SPS data rate optimized for low-noise load-cell measurements. The ADS1222IPWRG4 is a more general-purpose 24-bit ADC with a flexible multiplexer and programmable gain, which can be used in bridge applications but lacks the dedicated bridge-excitation control and fixed low-noise gain architecture of the ADS1230IPW. For direct load-cell interfacing with minimal external components, the ADS1230IPW is the more application-specific choice.
No. The two devices use different digital interfaces and register maps. The ADS1230IPW uses a simple two-wire interface with a dedicated data-ready signal and fixed gain/rate settings selected by pin strapping. The ADS1222IPWRG4 uses a serial peripheral interface with command-based register configuration for gain, data rate, multiplexer selection, and operating mode. Replacing one with the other requires firmware modification, PCB layout changes, and revalidation of the analog front-end performance.