ADS1246IPW vs ADS1286UB/2K5

ADS1246IPW과 ADS1286UB/2K5에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1246IPW and ADS1286UB/2K5 are not drop-in replacements for one another. The ADS1246IPW is a 24-bit delta-sigma ADC with an integrated PGA and SPI interface in a TSSOP-16 package, while the ADS1286UB/2K5 is a 12-bit successive-approximation ADC with a serial interface in an SOIC-8 package. Their resolution, conversion architecture, channel configuration, and footprint differ fundamentally, so substituting one for the other requires a full redesign of the signal chain, layout, and firmware rather than a direct swap.

Different resolution Different ADC architecture Different package and footprint Different interface and control

Parts at a glance

Part A

ADS1246IPW

텍사스 인스트루먼트(주)

Lifecycle
Active
Stock
6549 PCS
Package
TSSOP-16
Series
데이터 수집 - 아날로그 변환기(ADC)
Part B

ADS1286UB/2K5

텍사스 인스트루먼트(주)

Lifecycle
Active
Stock
8439 PCS
Package
SOIC-8
Series
데이터 수집 - 아날로그 변환기(ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1246IPW ADS1286UB/2K5 Why it matters
Resolution (bits) 24 12 Resolution determines the smallest signal change the ADC can distinguish; a 24-bit device offers far finer measurement granularity than a 12-bit device.
Number of input channels 1 differential 1 differential Both are single-channel devices, so channel count is not a differentiator for substitutability.
Interface type SPI SPI Both use SPI, so the host microcontroller interface is compatible between the two parts.
Supply voltage (analog) 2.7 V to 5.25 V 4.5 V to 5.5 V The ADS1246 supports lower supply voltages, allowing operation in 3.3 V systems where the ADS1286 would not function.
Package 16-TSSOP 8-SOIC Different package footprints and pin counts mean the parts are not drop-in replacements on an existing PCB.
Input type Differential Differential Both accept differential inputs, so signal conditioning topology can remain similar.
Internal PGA Yes (gain 1 to 128) No The ADS1246's programmable gain amplifier allows direct connection of low-level sensors, whereas the ADS1286 requires external amplification.
Data rate (max) 2 kSPS 20 kSPS The ADS1286 offers a higher maximum sample rate, which matters for faster-changing signals, while the ADS1246 trades speed for resolution.
Operating temperature range -40 °C to +105 °C -40 °C to +85 °C The wider temperature range of the ADS1246 suits harsher environments where the ADS1286 may exceed its rated limits.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1246IPW ADS1286UB/2K5
Supplier - Texas Instruments
Part Status Active Obsolete
Number of Bits 24 12
Sampling Rate(Per Second) 2k 20k
Number of Inputs 1 1
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration MUX-PGA-ADC S/H-ADC
Ratio - S / H: ADC - 1:1
Number of A/D Converters 1 1
Architecture Sigma-Delta SAR
Reference Type External, Internal External
Voltage - Supply, Analog 2.7V ~ 5.25V 5V
Voltage - Supply, Digital 2.7V ~ 5.25V 5V
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C
Features PGA, Temperature Sensor -

Frequently asked questions

What are the key architectural differences between the ADS1246IPW and the ADS1286UB/2K5?

The ADS1246IPW is a 24-bit delta-sigma analog-to-digital converter with a built-in programmable gain amplifier (PGA) and an SPI-compatible serial interface, housed in a TSSOP-16 package. The ADS1286UB/2K5 is a 12-bit successive-approximation register (SAR) ADC with a pseudo-differential input and a serial interface, supplied in a SOIC-8 package. The ADS1246 targets high-resolution, low-frequency measurement applications, while the ADS1286 targets faster, lower-resolution data acquisition.

How do the resolution and data rate specifications compare between the ADS1246IPW and ADS1286UB/2K5?

The ADS1246IPW provides 24-bit resolution with a programmable data rate up to 2 kSPS. The ADS1286UB/2K5 provides 12-bit resolution with a maximum throughput of 20 kSPS. The ADS1246 therefore offers significantly higher resolution at lower speed, whereas the ADS1286 offers higher speed at lower resolution.

Do the ADS1246IPW and ADS1286UB/2K5 have compatible digital interfaces?

Both devices use a serial interface, but they are not protocol-identical. The ADS1246IPW uses an SPI-compatible interface with dedicated command and data framing, while the ADS1286UB/2K5 uses a simpler serial output interface. Firmware and host controller timing must be revalidated when migrating between the two parts.

Can the ADS1246IPW and ADS1286UB/2K5 be used in the same supply voltage range?

The ADS1246IPW operates from an analog supply of 2.7 V to 5.25 V and a digital supply of 2.7 V to 5.25 V. The ADS1286UB/2K5 operates from a single 5 V supply. Designs migrating between the two must confirm that the system supply and reference levels satisfy the respective device requirements.

Are the ADS1246IPW and ADS1286UB/2K5 pin-to-pin or package compatible?

No. The ADS1246IPW is supplied in a 16-pin TSSOP package, while the ADS1286UB/2K5 is supplied in an 8-pin SOIC package. Pin count, pin functions, and PCB land patterns differ, so a direct drop-in replacement is not possible without a board redesign.

Which device is better suited for high-resolution sensor measurement versus fast data acquisition?

The ADS1246IPW, with its 24-bit delta-sigma architecture and integrated PGA, is better suited to high-resolution, low-frequency sensor measurement such as bridge and thermocouple signal conditioning. The ADS1286UB/2K5, with its 12-bit SAR architecture and 20 kSPS throughput, is better suited to faster, lower-resolution data acquisition tasks.

What input configuration differences should be considered when comparing the ADS1246IPW and ADS1286UB/2K5?

The ADS1246IPW provides a fully differential input with a programmable gain amplifier, supporting small-signal measurement with selectable gain. The ADS1286UB/2K5 provides a pseudo-differential input without an integrated PGA. Input signal conditioning and reference design must be reviewed separately for each device.