ADS124S06IPBS vs ADS1296IPAGR

ADS124S06IPBS과 ADS1296IPAGR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS124S06IPBS and ADS1296IPAGR are not drop-in replacements for one another. The ADS124S06IPBS is a 6-channel, 24-bit precision delta-sigma ADC with a single unipolar/bipolar supply and no integrated front-end, while the ADS1296IPAGR is a 6-channel, 24-bit biopotential front-end with integrated PGAs, internal reference, and ECG/EEG-specific features. Their pinouts, package footprints, supply architectures, and functional integration differ substantially, so a direct board-level substitution is not possible without redesign.

Different functional integration Different package footprint Different supply architecture Different input front-end

Parts at a glance

Part A

ADS124S06IPBS

텍사스 인스트루먼트(주)

Lifecycle
Active
Stock
2820 PCS
Package
TQFP-32
Series
데이터 수집 - 아날로그 변환기(ADC)
Part B

ADS1296IPAGR

텍사스 인스트루먼트(주)

Lifecycle
Active
Stock
9357 PCS
Package
TQFP-64
Series
데이터 수집 - 아날로그 프런트엔드(AFE)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS124S06IPBS ADS1296IPAGR Why it matters
Resolution (bits) 24 24 Both are 24-bit delta-sigma ADCs, so nominal resolution is equivalent for precision measurement applications.
Number of input channels 6 (single-ended) / 3 (differential) 8 (differential) Channel count determines how many signals can be digitized simultaneously; the ADS1296 offers more differential inputs for multi-lead biopotential sensing.
Typical application focus Precision sensor measurement (temperature, pressure, strain) Biopotential / ECG / EEG signal acquisition The intended application domain affects integrated features such as input bias, lead-off detection, and reference architecture, impacting functional substitutability.
Programmable gain amplifier (PGA) gain range 1 to 128 1 to 12 A wider PGA range allows the ADS124S06 to resolve smaller sensor signals directly, while the ADS1296 gain range is tailored to biopotential amplitudes.
Data output rate (max SPS) 4 kSPS 32 kSPS Maximum sample rate limits the bandwidth of signals that can be captured; the ADS1296 supports higher throughput for multi-channel biopotential sampling.
Supply voltage (analog) 2.7 V to 5.25 V (single supply) 2.7 V to 5.25 V (analog) with unipolar/bipolar options Supply compatibility affects whether the part can drop into an existing rail architecture without additional regulation.
Integrated features PGA, internal reference, IDAC, sensor excitation PGA, internal reference, lead-off detection, respiration impedance, pace detection On-chip feature sets differ substantially; the ADS1296 integrates biopotential-specific functions not present on the ADS124S06, limiting direct substitution.
Package TQFP-32 (PBS) TQFP-64 (PAG) Different package footprints and pin counts prevent pin-compatible board-level replacement between the two devices.
Interface SPI SPI Both use SPI, so host-side digital communication protocol is compatible, though register maps and command sets differ.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS124S06IPBS ADS1296IPAGR
Supplier - Texas Instruments
Part Status Active Active
Number of Bits 24 24
Number of Channels - 6
Power (Watts) - 17.5 mW
Voltage - Supply, Analog 2.7V ~ 5.25V 2.7V ~ 5.5V
Voltage - Supply, Digital 2.7V ~ 3.6V 1.65V ~ 3.6V
Mounting Type - Surface Mount
Sampling Rate(Per Second) 4k -
Number of Inputs 6 -
Input Type Single Ended -
Data Interface SPI -
Configuration MUX-PGA-ADC -
Ratio - S / H: ADC 0:1 -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External, Internal -
Features PGA -
Operating Temperature -50°C ~ 125°C -

Frequently asked questions

What are the primary functional differences between the ADS124S06IPBS and the ADS1296IPAGR?

The ADS124S06IPBS is a 24-bit, 6-channel delta-sigma ADC designed for precision sensor measurement, while the ADS1296IPAGR is a 24-bit, 6-channel simultaneous-sampling delta-sigma ADC with integrated ECG/EEG front-end features, including programmable gain amplifiers and lead-off detection, intended for biopotential measurement applications.

Do the ADS124S06IPBS and ADS1296IPAGR have the same package and pinout?

No. The ADS124S06IPBS is supplied in a 32-pin TQFP package, and the ADS1296IPAGR is supplied in a 64-pin TQFP package. The pin counts and pin functions differ, so they are not pin-to-pin compatible.

Are the ADS124S06IPBS and ADS1296IPAGR interchangeable in an existing design?

No. Differences in package footprint, pinout, channel architecture, integrated features, and typical application targets mean the two devices are not direct substitutes. Any replacement requires schematic, layout, and firmware validation against the respective manufacturer datasheets.

What are the input channel configurations of each device?

The ADS124S06IPBS provides 6 single-ended or 3 differential input channels with a flexible input multiplexer. The ADS1296IPAGR provides 6 simultaneous-sampling differential input channels, each with its own PGA and ADC, enabling correlated multi-channel acquisition.

Which device is better suited for precision industrial sensor measurement?

The ADS124S06IPBS is generally the more appropriate choice for precision industrial sensor measurement, as it is specified for low-noise, high-resolution measurement of signals such as RTDs, thermocouples, and bridge sensors, with integrated features such as a programmable gain amplifier and excitation current sources.

Which device is intended for biopotential or ECG/EEG applications?

The ADS1296IPAGR is intended for biopotential applications. It integrates six simultaneous-sampling 24-bit ADCs with PGAs and supports features such as lead-off detection and respiration measurement, which are relevant to ECG and EEG front-end designs.

Do both devices support SPI communication?

Yes. Both the ADS124S06IPBS and the ADS1296IPAGR provide an SPI-compatible serial interface for configuration and data readout, as documented in their respective manufacturer datasheets.

Can the ADS1296IPAGR replace the ADS124S06IPBS in a low-channel-count precision measurement design?

Not directly. Although both are 24-bit delta-sigma ADCs, the ADS1296IPAGR has a different package, pinout, channel architecture, and feature set optimized for biopotential acquisition. A replacement would require redesign and validation rather than a direct drop-in substitution.