AFE5816ZAV
텍사스 인스트루먼트(주)
- Lifecycle
- Active
- Stock
- 2161 PCS
- Package
- NFBGA-289
- Series
- 데이터 수집 - 아날로그 프런트엔드(AFE)
AFE5816ZAV과 AFE5808ZCF에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The AFE5816ZAV and AFE5808ZCF are both 8-channel ultrasound analog front ends from Texas Instruments sharing a common architecture and 15 mm × 9 mm NFBGA-289 footprint, making them strong functional replacement candidates. However, the AFE5816ZAV offers a higher maximum sampling rate (65 MSPS versus 50 MSPS) and a different package designation (ZAV versus ZCF), so the system clock, digital interface timing, and board-level thermal and layout assumptions must be validated before substitution.
텍사스 인스트루먼트(주)
텍사스 인스트루먼트(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AFE5816ZAV | AFE5808ZCF | Why it matters |
|---|---|---|---|
| Number of Channels | 16 | 8 | Channel count determines how many transducer elements can be processed simultaneously, directly affecting system architecture and board layout. |
| ADC Resolution | 14 bit | 12 bit | Higher ADC resolution provides greater dynamic range and finer signal detail, which impacts image quality in ultrasound receive chains. |
| Max Sampling Rate | 65 MSPS | 65 MSPS | Sampling rate sets the maximum signal bandwidth the ADC can digitize; matching rates ease timing and clocking reuse across designs. |
| LNA Gain Range | 12 dB to 30 dB | 12 dB to 30 dB | Low-noise amplifier gain range determines sensitivity to weak echoes and overall receive-chain noise performance. |
| Total Power per Channel | Approx. 50 mW/ch | Approx. 65 mW/ch | Power per channel affects thermal design and battery life in portable ultrasound systems; lower power enables denser channel counts. |
| Package | NFBGA (ZAV) | NFBGA (ZCF) | Package footprint and pinout must match the PCB layout; differing packages require board redesign for substitution. |
| Continuous Wave (CW) Doppler Support | Yes | Yes | CW Doppler capability is required for blood-flow velocity measurement; both supporting it preserves that clinical function. |
| Operating Temperature Range | 0°C to 70°C | 0°C to 70°C | Temperature range must cover the target application environment; matching ranges ensure equivalent reliability in the same system. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE5816ZAV | AFE5808ZCF |
|---|---|---|
| Supplier | - | Rochester Electronics, LLC,Texas Instruments |
| Part Status | Active | Active |
| Number of Bits | 12, 14 | 12, 14 |
| Number of Channels | 16 | 8 |
| Power (Watts) | 94 mW | 158 mW |
| Voltage - Supply, Analog | 1.7V ~ 2V, 3V ~ 3.3V | 1.7V ~ 1.9V, 3.15V ~ 3.6V, 5V |
| Voltage - Supply, Digital | 1.15V ~ 1.25V, 1.7V ~ 1.9V | 1.7V ~ 1.9V |
| Mounting Type | Surface Mount | Surface Mount |
The AFE5816ZAV and AFE5808ZCF are fully integrated analog front-end (AFE) devices from Texas Instruments designed for ultrasound imaging systems. Both integrate a low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), and analog-to-digital converter (ADC) into a single device.
The AFE5816ZAV is an 8-channel AFE, while the AFE5808ZCF is also an 8-channel AFE. Both devices provide eight independent receive channels in a single package.
The AFE5816ZAV integrates a 14-bit ADC with a maximum sampling rate of 65 MSPS. The AFE5808ZCF integrates a 12-bit ADC with a maximum sampling rate of 65 MSPS. The primary difference is ADC resolution (14-bit vs. 12-bit).
No. The AFE5816ZAV is offered in a 289-ball NFBGA (ZAV) package, while the AFE5808ZCF is offered in a 289-ball NFBGA (ZCF) package. Both are 289-ball NFBGA packages, but the package designators differ, so PCB land patterns and pinouts should be verified against the respective datasheets before substitution.
The AFE5816ZAV typically consumes approximately 1.1 W total across 8 channels at 65 MSPS. The AFE5808ZCF typically consumes approximately 1.0 W total across 8 channels at 65 MSPS. Exact power depends on operating conditions and should be confirmed from the respective datasheets.
No, they should not be treated as drop-in replacements. Although both are 8-channel ultrasound AFEs in 289-ball NFBGA packages, they differ in ADC resolution (14-bit vs. 12-bit), package designator (ZAV vs. ZCF), and pinout. A direct substitution requires full validation of pin compatibility, digital interface timing, and system performance against the target design.
Both the AFE5816ZAV and AFE5808ZCF provide LVDS serialized digital output for the ADC data. The exact output data format and lane configuration should be verified in the respective device datasheets, as the 14-bit and 12-bit ADC resolutions result in different output data widths.
Both devices are intended for medical ultrasound imaging systems, including portable and cart-based ultrasound scanners, as well as other high-channel-count receive applications requiring integrated LNA, VCA, PGA, and ADC signal chains.