AMC1300BDWVR vs AMC1300DWVR

AMC1300BDWVR과 AMC1300DWVR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AMC1300BDWVR is a functional replacement candidate for the AMC1300DWVR, sharing the same isolated amplifier function, SOIC-8 package, and gain architecture, with the B-grade variant offering a tighter maximum gain error tolerance. Designers should validate the tightened gain error specification against their measurement accuracy budget before substituting in precision current-sensing or shunt-monitor applications.

Package Type High match
Isolation Rating High match
Gain Error Tolerance Validation required
Input Offset Voltage Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AMC1300DWVR AMC1300BDWVR Why it matters
Input Voltage Range ±250 mV ±50 mV Defines the differential signal swing the isolated amplifier can accept; the B variant is optimized for lower shunt voltage drops, affecting measurable current range and shunt sizing.
Fixed Gain 8.2 V/V 41 V/V Gain sets the output scaling relative to input; the higher gain of the B variant provides greater resolution for small shunt signals but reduces full-scale input range.
Input Full-Scale Range ±250 mV ±50 mV Determines the maximum differential input before clipping; critical for matching to the shunt resistor voltage and avoiding saturation in current-sense designs.
Input Offset Voltage (max) ±0.3 mV ±0.05 mV Lower offset improves DC accuracy at zero current; the B variant offers tighter offset, which matters for precision low-current measurement.
Input Offset Drift (max) ±3 µV/°C ±1 µV/°C Offset drift affects accuracy over temperature; the B variant's lower drift supports more stable measurements across the operating temperature range.
Gain Error (max) ±0.3% ±0.2% Gain error impacts absolute accuracy of the measured signal; tighter gain error in the B variant improves overall measurement precision.
Input Bandwidth 310 kHz 280 kHz Bandwidth limits the maximum signal frequency that can be accurately amplified; relevant for control-loop response and transient current sensing.
Input Resistance 22 kΩ 4.1 kΩ Input resistance loads the shunt and affects measurement error; the lower input resistance of the B variant requires careful shunt and filter design.
Common-Mode Input Range -0.16 V to 0.16 V (relative to GND1) -0.05 V to 0.05 V (relative to GND1) Constrains the allowable common-mode voltage on the input pins; affects compatibility with shunt placement and grounding in the high-voltage domain.
Isolation Rating 5000 V RMS (reinforced) 5000 V RMS (reinforced) Isolation rating determines safety and voltage withstand between high- and low-voltage domains; both variants share the same reinforced isolation, so it is not a differentiator.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AMC1300BDWVR AMC1300DWVR
Part Status Active Active
Type Isolation Isolation
Applications Current Sensing, Power Management Current Sensing, Power Management
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What is the primary difference between the AMC1300DWVR and the AMC1300BDWVR?

The AMC1300DWVR and AMC1300BDWVR are both isolated amplifiers in a 5.00 mm × 6.20 mm SOIC-8 (DWV) package, but they differ in their input voltage range and corresponding gain. The AMC1300DWVR is specified with an input voltage range of ±250 mV and a fixed gain of 8.2, while the AMC1300BDWVR is specified with an input voltage range of ±50 mV and a fixed gain of 41. Both devices share the same isolation rating, supply requirements, and pinout.

Are the AMC1300DWVR and AMC1300BDWVR pin-to-pin compatible?

Yes. Both devices are offered in the same 8-pin SOIC (DWV) package with identical pin functions: VDD1, INP, INN, GND1 on the input side and VDD2, OUTP, OUTN, GND2 on the output side. This allows the two variants to share the same PCB footprint and land pattern.

What isolation rating do the AMC1300DWVR and AMC1300BDWVR provide?

Both devices are reinforced isolated amplifiers rated for 5000 VRMS isolation per UL 1577 and provide a working voltage of 1500 VDC (or 1060 VPK) per VDE V 0884-11. They also offer a high common-mode transient immunity of 150 kV/µs, making them suitable for high-voltage industrial measurement applications.

Can the AMC1300BDWVR directly replace the AMC1300DWVR in an existing design?

Not without design validation. Although the devices are pin-compatible and share the same package and isolation ratings, the AMC1300BDWVR has a ±50 mV input range and a gain of 41, whereas the AMC1300DWVR has a ±250 mV input range and a gain of 8.2. A replacement requires re-scaling the shunt resistor and signal chain so that the full-scale input and output voltage levels remain within the downstream ADC or controller's acceptable range.

What are the supply voltage requirements for the AMC1300DWVR and AMC1300BDWVR?

Both devices operate from a high-side supply (VDD1) of 3.0 V to 5.5 V and a low-side supply (VDD2) of 3.0 V to 5.5 V. The two supplies are isolated from each other, and each side has its own ground (GND1 and GND2). Typical quiescent current is approximately 6.5 mA per side at 5 V.

What bandwidth and response characteristics do these isolated amplifiers offer?

Both the AMC1300DWVR and AMC1300BDWVR provide a typical bandwidth of 310 kHz and a typical propagation delay of 2.5 µs. These characteristics support accurate current and voltage sensing in motor drive, inverter, and industrial measurement applications where fast feedback is required.

What is the operating temperature range for the AMC1300DWVR and AMC1300BDWVR?

Both devices are specified for an operating ambient temperature range of –40 °C to +125 °C, which supports use in industrial and automotive-adjacent environments. The DWV package is also qualified to the same temperature range for both variants.

Which applications are best suited to each variant?

The AMC1300DWVR, with its ±250 mV input range and gain of 8.2, is typically used for shunt-based current sensing where a larger shunt voltage is available. The AMC1300BDWVR, with its ±50 mV input range and gain of 41, is intended for low-voltage shunt sensing where a smaller shunt drop is preferred to reduce power dissipation. Both are suited to motor drives, inverters, and isolated voltage/current measurement in industrial systems.