AMC1302QDWVRQ1 vs AMC1302DWVR

AMC1302QDWVRQ1과 AMC1302DWVR에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AMC1302QDWVRQ1 is a functionally compatible candidate for the AMC1302DWVR, sharing the same isolated amplifier core, package footprint, and gain characteristics, with the automotive-qualified variant adding AEC-Q100 qualification for use in the same signal-chain designs.

Package Type High match
Gain and Input Range High match
Isolation Rating High match
Qualification Grade Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AMC1302DWVR AMC1302QDWVRQ1 Why it matters
Input Voltage Range ±50 mV ±50 mV Defines the differential signal span the isolated amplifier can accept; identical range means the same shunt/sensor front-end can be reused.
Gain 41 41 Fixed gain determines the output scaling relative to input; matching gain preserves the downstream ADC scaling and calibration.
Isolation Rating 5000 Vrms (reinforced) 5000 Vrms (reinforced) Reinforced isolation voltage is critical for safety and working-voltage compliance in high-voltage measurement paths.
Supply Voltage 3.0 V to 5.5 V (both sides) 3.0 V to 5.5 V (both sides) Compatible supply rails allow the same power architecture on both high and low sides without redesign.
Bandwidth 1 MHz 1 MHz Signal bandwidth affects achievable control-loop response and measurement fidelity for current sensing.
Operating Temperature Range -40°C to +125°C -40°C to +125°C Temperature range determines suitability for automotive and industrial environments; matching ranges support drop-in substitution.
Qualification / Grade Industrial grade AEC-Q100 qualified (automotive) The Q1 variant is automotive-qualified, which is required for automotive designs but may carry different cost and documentation.
Package / Pin Count 8-pin SOIC (DWV) 8-pin SOIC (DWV) Package and pinout compatibility is essential for physical board-level substitution; both share the same DWV footprint.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AMC1302QDWVRQ1 AMC1302DWVR
Part Status Active Active
Type - Isolation
Applications - Current Sensing, Power Management
Mounting Type - Surface Mount

Frequently asked questions

What is the primary difference between the AMC1302DWVR and the AMC1302QDWVRQ1?

The AMC1302DWVR is the industrial-grade version, while the AMC1302QDWVRQ1 is the automotive-grade version qualified to AEC-Q100 Grade 1. Both are isolated amplifiers in the same SOIC-8 (DWV) package with identical core isolation amplifier functionality, but the Q1 variant is tested and qualified for automotive applications requiring higher reliability and temperature range compliance.

Are the AMC1302DWVR and AMC1302QDWVRQ1 pin-compatible and package-compatible?

Yes. Both devices are offered in the same 8-pin SOIC (DWV) package with the same pinout, allowing them to share the same PCB land pattern. However, substitution between them should be validated against the specific application's qualification and reliability requirements.

What is the input voltage range of the AMC1302DWVR and AMC1302QDWVRQ1?

Both devices are isolated amplifiers designed for shunt-based current sensing with a specified input voltage range of ±50 mV (full-scale input range of ±50 mV), optimized for use with low-value shunt resistors in current-sensing applications.

What isolation rating do the AMC1302DWVR and AMC1302QDWVRQ1 provide?

Both devices provide reinforced isolation with a maximum isolation voltage rating of 5000 VRMS per UL 1577 and a working voltage of 1500 VDC per VDE V 0884-11, making them suitable for high-voltage current-sensing applications requiring reinforced isolation.

What is the operating temperature range for each variant?

The AMC1302DWVR is specified over the industrial temperature range of –40°C to +125°C. The AMC1302QDWVRQ1 is AEC-Q100 Grade 1 qualified and specified over the automotive temperature range of –40°C to +125°C, with additional automotive qualification testing and documentation.

Can the AMC1302QDWVRQ1 be used in industrial applications, and can the AMC1302DWVR be used in automotive applications?

The AMC1302QDWVRQ1 can be used in industrial applications since it meets or exceeds the industrial specifications. The AMC1302DWVR, however, is not AEC-Q100 qualified and should not be used in automotive applications requiring Q1 qualification. Selection should be based on the end application's qualification requirements.

What output interface do the AMC1302DWVR and AMC1302QDWVRQ1 provide?

Both devices provide a differential analog output with a fixed gain of 8.2 V/V and a nominal output common-mode voltage of 1.44 V, designed to interface directly with differential-input ADCs in isolated current-sensing signal chains.

Do the AMC1302DWVR and AMC1302QDWVRQ1 share the same supply voltage requirements?

Yes. Both devices operate with a high-side supply (VDD1) of 3.0 V to 5.5 V and a low-side supply (VDD2) of 3.0 V to 5.5 V, allowing flexible supply configuration on both sides of the isolation barrier.