AFE4432YCHR

이미지는 참조용입니다.

AFE4432YCHR

+BOM

ULTRA-SMALL, ULTRA-LOW-POWER, HI

  • 제조업체텍사스 인스트루먼트(주)

  • 제조업체 부품 #AFE4432YCHR

  • 재고19054

365 1일 품질 보증

7*24 영업 시간 서비스 보증

90-판매 후 1일 보증

정품 보증

사양

속성 가치
Part Status Active
Number of Bits 22
Number of Channels 3
Voltage - Supply, Analog 1.7V ~ 1.9V, 3V ~ 5.5V
Voltage - Supply, Digital 1.7V ~ 1.9V, 3V ~ 5.5V
Mounting Type Surface Mount
Package 25-XFBGA, DSBGA
Supplier Device Package 25-DSBGA (1.8x1.92)
Packaging Bulk

개요

Description

The AFE4432YCHR is Texas Instruments’ analog front end designed for optical biosensing, notably pulse oximetry and photoplethysmography (PPG) in wearables and medical devices. It integrates LED drive circuitry, photodiode transimpedance amplification, programmable gain stages, digital filters, and a high-resolution ADC with a digital interface, enabling sensor-to-digital conversion with low noise and low power. Key features typically include dual LED drivers (red and infrared), multi-channel sensing, ambient-light cancellation, wide dynamic range, and programmable sampling. The YCHR suffix denotes the packaging/lead-free RoHS-compliant option. Common applications are finger-clip/pad oximeters, wearable health monitors, and compact medical devices. For exact electrical specs (supply voltages, LED current range, data rate, input bandwidth), consult the current datasheet and product page.

Pinout

- Pin count: 16 pins (16-pin package).
- Function: Analog front-end for optical biosensors (photoplethysmography). Provides LED drive current sources and a transimpedance/instrumentation amplifier front end with filtering to interface a photodiode to an ADC.

Manufacturer

- Manufacturer: Texas Instruments (TI).
- What kind of company: TI is a global semiconductor company that designs and manufactures analog and embedded processing integrated circuits used in a wide range of electronics across automotive, industrial, consumer, and communications markets.

Application

AFE4432YCHR is a low-noise optical analog front-end for pulse oximetry and heart-rate sensing. Typical application areas include:
- Wearable health devices (smartwatches, fitness trackers) for HR and SpO2 monitoring
- Medical/consumer pulse oximeters (finger or earlobe sensors)
- Portable or home healthcare systems using photoplethysmography (PPG)
- Any SpO2/HR sensing application requiring LED drive and signal conditioning with ADC in a compact package

Package

Lead Frame Chip Scale Package (LFCSP), 24-pin, 4×4 mm body.

AFE4432YCHR과 관련된 제품