이미지는 참조용입니다.
SCD41
+BOMCOMP STIRRUP W/CONTAX 3/0-3/0 AS
-
제조업체ABB Electrification (Thomas and Betts)
-
제조업체 부품 #SCD41
-
재고11207
365 1일 품질 보증
7*24 영업 시간 서비스 보증
90-판매 후 1일 보증
정품 보증
사양
| 속성 | 가치 |
| PartStatus | Active |
| Packaging | Bulk |
개요
Description
Key points:
- Small form factor and easy integration
- Low power with fast response
- Automatic Baseline Calibration (ABC) to track outdoor CO2 levels
- Factory-calibrated with option for user calibration
- Provides CO2, temperature, and humidity data digitally
Typical use cases:
- Indoor air quality monitoring
- HVAC and building automation
- Demand-controlled ventilation
- Smart home and portable devices
In short, SCD41 delivers accurate, low‑power CO2 sensing with temperature and humidity compensation in a ready-to-use digital package.
Equivalent
- Sensirion SCD30, SCD40 (same family)
- Senseair modules (S8, Sunrise, K30)
- Cubic/COZIR CO2 modules (COZIR series)
- Winsen MH‑Z19 / MH‑Z19B
- Amphenol/Telaire modules (T6615, T6713)
Compare size, accuracy, power, interfaces and calibration requirements before substituting.
Features
- CO2 measurement: 400–5,000 ppm with high accuracy (NDIR core) for indoor air quality.
- Temperature compensation: built-in temperature sensor used to correct CO2 readings.
- Interface: digital I2C interface; supports multiple devices on the same bus; operates from common logic voltages.
- Power and modes: low-power operation with selectable measurement modes and sleep/wake options.
- Calibration: Automatic Baseline Calibration (ABC) for long-term drift correction; options for forced calibration.
- Size and robustness: compact surface-mount LGA package suitable for compact sensors and devices.
- Response and update: fast CO2 response with configurable measurement cycle (typ. around 1 Hz, configurable).
- Humidity: does not measure humidity itself; if RH data is required, pair with a separate Sensirion humidity sensor (e.g., SHT series).
Note: Specific electrical ranges, currents, and accuracy may vary by revision; consult the latest datasheet for exact numbers.
Pinout
Pin functions (I2C interface):
- VDD: supply power
- GND: ground
- SCL: I2C clock
- SDA: I2C data
- ADDR: I2C address select
- ALERT/RESET: interrupt/alert output or reset input (used for status/data ready)
Manufacturer
Application
- Building automation and HVAC: demand-controlled ventilation, energy optimization
- Indoor air quality monitoring: offices, schools, hospitals, commercial spaces
- Smart home and consumer devices: air-quality meters, purifiers, thermostats
- Industrial and controlled environments: labs, data centers, cleanrooms
- IoT / smart city sensing: IAQ sensor networks and environmental monitoring nodes
Note: follows compact, low-power, digital (I2C) CO2 + temp/humidity sensing.