AD8497ARMZ vs AD8494ARMZ

AD8497ARMZ과 AD8494ARMZ에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD8497ARMZ and AD8494ARMZ are both thermocouple amplifier ICs from the same AD849x family in identical 8-lead MSOP packages, sharing the same supply range, output configuration, and pinout. They differ primarily in their factory-set thermocouple type and corresponding temperature range, so the AD8497ARMZ can serve as a functional substitute for the AD8494ARMZ only when the application's thermocouple type and measurement range align with the AD8497's calibration.

Package Type High match
Output Type High match
Thermocouple Type Validation required
Temperature Range Validation required

Parts at a glance

Part A

AD8497ARMZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
6084 PCS
Package
MSOP-8
Series
커넥터 - 센서 및 탐지기 커넥터
Part B

AD8494ARMZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
9077 PCS
Package
TSSOP-8
Series
커넥터 - 센서 및 탐지기 커넥터

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD8497ARMZ AD8494ARMZ Why it matters
Sensor Type J-Type Thermocouple K-Type Thermocouple Determines which thermocouple the amplifier is calibrated for; using the wrong type produces large temperature measurement errors.
Output Voltage at 25°C (Vout) 5 mV/°C scaled for J-type (approx. 1.25 V at 25°C ambient reference) 5 mV/°C scaled for K-type (approx. 1.25 V at 25°C ambient reference) The output scaling must match the thermocouple curve so downstream ADCs interpret temperature correctly.
Thermocouple Sensitivity Range Optimized for J-type (~50 µV/°C nominal) Optimized for K-type (~41 µV/°C nominal) Internal gain and cold-junction compensation are trimmed to the specific thermocouple's Seebeck coefficient.
Temperature Range (Measurement) 0°C to +750°C (J-type range) 0°C to +1200°C (K-type range) Defines the usable measurement span; K-type supports higher temperatures than J-type.
Supply Voltage Range 2.7 V to 18 V (single supply) 2.7 V to 18 V (single supply) Both parts share the same supply flexibility, so power design is interchangeable.
Supply Current ~180 µA typical ~180 µA typical Low quiescent current suits battery-powered and low-power instrumentation in both cases.
Package 8-Lead MSOP (RMZ) 8-Lead MSOP (RMZ) Identical footprint allows drop-in PCB replacement without layout changes.
Operating Temperature Range −40°C to +125°C −40°C to +125°C Same industrial temperature rating means equivalent environmental robustness.
Output Type Analog voltage (ratiometric to temperature) Analog voltage (ratiometric to temperature) Both provide a linear analog output, so the same ADC front-end can be reused.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD8497ARMZ AD8494ARMZ
Supplier - Analog Devices Inc.
Part Status Active Active
Type Thermocouple Amplifier Thermocouple Amplifier
Input Type Differential Differential
Output Type Analog Analog
Supply Current 250 µA 250 µA
Operating Temperature 25°C ~ 100°C 0°C ~ 50°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the AD8497ARMZ and AD8494ARMZ?

Both are thermocouple amplifiers with cold junction compensation from Analog Devices, packaged in an 8-lead MSOP (RMZ). The AD8494 is factory-trimmed for a J-type thermocouple (0°C to 50°C reference, 5 mV/°C nominal output), while the AD8497 is factory-trimmed for a K-type thermocouple (25°C reference, 5 mV/°C nominal output).

What is the key difference between the AD8497ARMZ and AD8494ARMZ?

The primary difference is the thermocouple type and reference junction temperature they are trimmed for: the AD8494ARMZ is calibrated for J-type thermocouples with a 0°C reference, and the AD8497ARMZ is calibrated for K-type thermocouples with a 25°C reference. This affects the output voltage-to-temperature transfer function and the usable measurement range.

Can the AD8497ARMZ and AD8494ARMZ be used interchangeably?

No, they are not direct substitutes. Because each is trimmed for a different thermocouple type and reference junction temperature, swapping them changes the temperature-to-voltage mapping and introduces measurement error unless the system is recalibrated for the alternate device and thermocouple type.

What is the nominal output voltage scaling of these devices?

Both devices provide a nominal output sensitivity of 5 mV/°C. The absolute output voltage at a given temperature differs because the AD8494ARMZ uses a 0°C reference and the AD8497ARMZ uses a 25°C reference, so the output offset differs between the two parts.

Do the AD8497ARMZ and AD8494ARMZ share the same package and pinout?

Yes, both are offered in the same 8-lead MSOP package (suffix ARMZ) with the same pin functions, including the thermocouple inputs, reference, output, and supply pins. The package and pinout are common, but the internal trimming differs.

What supply voltage do the AD8497ARMZ and AD8494ARMZ require?

Both devices operate from a single supply over the 2.7 V to 18 V range (or split supplies within that total), as specified in the Analog Devices datasheet. The wide supply range supports both low-voltage and higher-voltage industrial signal chains.

Which device should be selected for a K-type versus J-type thermocouple design?

Select the AD8497ARMZ for K-type thermocouples and the AD8494ARMZ for J-type thermocouples. Matching the device trim to the thermocouple type preserves the factory calibration and avoids the need for external cold junction compensation or recalibration.