ADF4001BCPZ
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 1703 PCS
- Package
- WFQFN-20
- Series
- 클럭 타이밍 - 클럭 발생기, PLL, 주파수 합성기
ADF4001BCPZ과 ADF4007BCP에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADF4001BCPZ and ADF4007BCP are not drop-in replacements for one another. Although both are integer-N PLL frequency synthesizers from Analog Devices, they differ in maximum operating frequency, reference input frequency, package footprint, and supply voltage range, so a direct board-level substitution is not possible without design changes.
아날로그 디바이스(주)
아날로그 디바이스(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADF4001BCPZ | ADF4007BCP | Why it matters |
|---|---|---|---|
| Function Type | Integer-N PLL frequency synthesizer | Dual integer-N PLL frequency synthesizer | Defines the core role of the device; a dual PLL can drive two loops, while a single PLL drives one, affecting system architecture. |
| Number of PLLs | 1 | 2 | Determines how many independent frequency loops the chip can control, directly impacting board space and design complexity. |
| Maximum RF Input Frequency | 200 MHz | 1 GHz | Sets the upper limit of the input signal the prescaler/PLL can handle, affecting usable frequency range. |
| Prescaler | 8/9, 16/17, 32/33, 64/65 | 8/9 | Prescaler options affect the achievable division ratios and thus the output frequency resolution and range. |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V | Determines compatibility with the system power rail; identical ranges ease drop-in substitution. |
| Package | 20-Lead LFCSP (CP-20-1) | 20-Lead LFCSP (CP-20-1) | Package footprint and pinout must match for physical board compatibility. |
| Operating Temperature Range | -40°C to +85°C | -40°C to +85°C | Confirms the device can operate in the same environmental conditions. |
| Charge Pump Current | Programmable (up to 5 mA) | Programmable (up to 5 mA) | Charge pump current affects loop filter design and lock time; matching values simplify reuse of loop filter components. |
| Interface | 3-wire serial (SPI-compatible) | 3-wire serial (SPI-compatible) | Programming interface compatibility allows reuse of the same microcontroller firmware and bus wiring. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADF4001BCPZ | ADF4007BCP |
|---|---|---|
| Supplier | - | Rochester Electronics, LLC |
| Part Status | Active | Obsolete |
| Type | Clock Generator (RF) | Clock/Frequency Synthesizer (RF) |
| PLL | Yes | Yes |
| Input | CMOS, TTL | CMOS |
| Output | Clock | Clock |
| Ratio - Input: Output | 2:1 | 2:1 |
| Differential - Input: Output | Yes/No | Yes/No |
| Frequency - Max | 200MHz | 7.5GHz |
| Divider / Multiplier | Yes/No | Yes/No |
| Voltage - Supply | 2.7V ~ 5.5V | 2.7V ~ 3.3V |
| Mounting Type | Surface Mount | Surface Mount |
| Number of Circuits | 1 | - |
| Operating Temperature | -40°C ~ 85°C | - |
The ADF4001BCPZ is a single integer-N PLL frequency synthesizer with an on-chip charge pump, specified for RF operation up to 200 MHz, and is supplied in a 20-lead LFCSP package. The ADF4007BCP is a dual integer-N PLL frequency synthesizer with two independent charge pumps, specified for RF operation up to 1.2 GHz, and is supplied in a 20-lead LFCSP package. The ADF4007BCP integrates two complete PLLs in one package, whereas the ADF4001BCPZ integrates one.
No. Although both devices are offered in a 20-lead LFCSP package, they are not pin-compatible. The ADF4001BCPZ provides a single PLL with one charge pump output, while the ADF4007BCP provides two independent PLLs with two charge pump outputs and additional control and supply pins. The PCB land patterns and pin functions differ, so the two devices cannot be interchanged on the same layout without redesign.
The ADF4001BCPZ is specified for RF input frequencies up to 200 MHz. The ADF4007BCP is specified for RF input frequencies up to 1.2 GHz. Designs requiring operation above 200 MHz should use the ADF4007BCP or another device rated for the required frequency.
The ADF4001BCPZ integrates one integer-N PLL and one charge pump. The ADF4007BCP integrates two independent integer-N PLLs and two charge pumps, allowing two separate loops to be implemented in a single package.
Both the ADF4001BCPZ and the ADF4007BCP are specified for a supply voltage range of 2.7 V to 3.3 V. Designs should ensure the supply remains within this range and that decoupling and layout follow the manufacturer's datasheet recommendations.
No. The ADF4001BCPZ provides only one PLL and one charge pump, while the ADF4007BCP provides two independent PLLs and two charge pumps. In addition, the pin functions and maximum RF input frequency differ (200 MHz versus 1.2 GHz). A direct drop-in replacement is not possible; any substitution requires validation against the manufacturer datasheet and the target design requirements.
Both devices are supplied in a 20-lead LFCSP (lead frame chip scale package). The package type is the same, but the pin assignments and internal functions differ between the two devices, so they are not interchangeable on a common PCB layout.
The ADF4007BCP should be selected for applications requiring two independent PLL loops, because it integrates two integer-N PLLs and two charge pumps in a single package. The ADF4001BCPZ provides only a single PLL and is not suitable for dual-loop architectures without an additional external PLL device.