ADM3050EBRIZ vs ADM3065ETRZ-EP-R7

ADM3050EBRIZ과 ADM3065ETRZ-EP-R7에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADM3050EBRIZ and ADM3065ETRZ-EP-R7 are not functionally interchangeable: the ADM3050EBRIZ is an isolated CAN transceiver, while the ADM3065ETRZ-EP-R7 is a non-isolated RS-485 transceiver. They differ in bus protocol, isolation, data rate, and package, so substitution requires a full system redesign rather than a direct swap.

Different bus protocol Isolation not present Different data rate Different package

Parts at a glance

Part A

ADM3050EBRIZ

아날로그 디바이스(주)

Lifecycle
Active
Stock
5255 PCS
Package
SOIC-8
Series
인터페이스 - 드라이브, 수신기, 트랜시버

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADM3050EBRIZ ADM3065ETRZ-EP-R7 Why it matters
Function / Protocol Isolated CAN transceiver (CAN FD capable) Isolated RS-485/RS-422 transceiver These devices serve different bus protocols (CAN vs RS-485), so they are not functionally interchangeable in a given network.
Data Rate Up to 12 Mbps (CAN FD) Up to 50 Mbps Maximum signaling rate determines whether the part meets the bandwidth requirements of the bus and cabling.
Isolation Rating 5 kV rms (galvanic isolation) 5 kV rms (galvanic isolation) Isolation voltage rating is critical for safety and ground-loop immunity in industrial and medical systems.
Supply Voltage 5 V (single supply) 3.0 V to 5.5 V Supply range affects compatibility with the host logic and power rail design of the target system.
Duplex / Channel Configuration Half-duplex CAN (single differential pair) Half-duplex RS-485 Duplex configuration must match the bus topology and the transceiver's role on the network.
Package 20-lead SOIC (wide body) 8-lead SOIC Package footprint and pin count determine PCB layout compatibility and whether a drop-in replacement is possible.
Operating Temperature Range -40 °C to +125 °C -55 °C to +125 °C (EP grade) Temperature range affects suitability for harsh environments and extended-temperature applications.
ESD Protection (Bus Pins) ±8 kV contact / ±15 kV air (IEC 61000-4-2) ±8 kV contact / ±15 kV air (IEC 61000-4-2) Bus-pin ESD robustness influences field reliability and the need for external protection components.
Fail-Safe Receiver Yes (CAN dominant/recessive handling) Yes (open/short fail-safe) Fail-safe behavior ensures a defined logic state when the bus is idle, open, or shorted, preventing indeterminate outputs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADM3050EBRIZ ADM3065ETRZ-EP-R7
Supplier - Analog Devices Inc.
Part Status Active Active
Type Transceiver, Isolated Transceiver
Protocol CAN RS485
Number of Drivers/Receivers 1/1 1/1
Duplex - Half
Receiver Hysteresis 150 mV 30 mV
Data Rate 12Mbps 50Mbps
Voltage - Supply 0.5V ~ 6V 3V ~ 5.5V
Operating Temperature -40°C ~ 125°C -55°C ~ 125°C
Mounting Type Surface Mount Surface Mount
Series iCoupler® -

Frequently asked questions

What are the primary functional differences between the ADM3050EBRIZ and the ADM3065ETRZ-EP-R7?

The ADM3050EBRIZ is a 5 kV rms isolated, CAN FD transceiver compliant with ISO 11898-2:2016, supporting data rates up to 12 Mbps. The ADM3065ETRZ-EP-R7 is a 3.3 V, non-isolated RS-485/RS-422 transceiver with ±15 kV ESD protection (IEC 61000-4-2) and data rates up to 50 Mbps. The ADM3050EBRIZ integrates galvanic isolation for CAN bus applications, while the ADM3065ETRZ-EP-R7 is a non-isolated RS-485 transceiver without isolation.

Are the ADM3050EBRIZ and ADM3065ETRZ-EP-R7 pin-to-pin compatible?

No. The ADM3050EBRIZ is supplied in a 16-lead SOIC_W package (R-16-2), while the ADM3065ETRZ-EP-R7 is supplied in an 8-lead SOIC_N package (R-8). The pin counts, pin functions, and package footprints differ, so they are not pin-to-pin compatible and cannot be directly substituted on the same PCB land pattern.

What are the supported data rates for each device?

The ADM3050EBRIZ supports CAN FD data rates up to 12 Mbps, per its datasheet. The ADM3065ETRZ-EP-R7 supports RS-485/RS-422 data rates up to 50 Mbps. The applicable data rate depends on the bus protocol and cable/termination design.

What isolation rating does the ADM3050EBRIZ provide, and does the ADM3065ETRZ-EP-R7 provide isolation?

The ADM3050EBRIZ provides 5 kV rms galvanic isolation (per UL 1577) between the logic side and the CAN bus side. The ADM3065ETRZ-EP-R7 is a non-isolated RS-485/RS-422 transceiver and does not provide galvanic isolation; system-level isolation would need to be added externally if required.

What supply voltages do the ADM3050EBRIZ and ADM3065ETRZ-EP-R7 require?

The ADM3050EBRIZ operates from a single 5 V supply (VCC = 4.5 V to 5.5 V) on the logic side and an isolated 5 V supply (VIO = 4.5 V to 5.5 V) on the bus side, per its datasheet. The ADM3065ETRZ-EP-R7 operates from a single 3.3 V supply (VCC = 3.0 V to 3.6 V). Supply voltage compatibility must be verified against the target design.

What ESD protection is specified for the ADM3065ETRZ-EP-R7?

The ADM3065ETRZ-EP-R7 specifies ±15 kV ESD protection on the RS-485/RS-422 bus pins per IEC 61000-4-2 (contact and air discharge), and ±15 kV per Human Body Model (HBM) on the bus pins, as stated in its datasheet. The ADM3050EBRIZ datasheet specifies ESD ratings for its CAN bus pins; designers should consult the respective datasheets for exact ESD test conditions and levels.

Which device is better suited for isolated CAN bus applications?

The ADM3050EBRIZ is the appropriate choice for isolated CAN FD applications because it integrates 5 kV rms galvanic isolation and ISO 11898-2:2016-compliant CAN FD transceiver functionality in a single package. The ADM3065ETRZ-EP-R7 is an RS-485/RS-422 transceiver and is not intended for CAN bus protocols.

What are the operating temperature ranges for the ADM3050EBRIZ and ADM3065ETRZ-EP-R7?

The ADM3050EBRIZ is specified for the industrial temperature range of −40°C to +125°C. The ADM3065ETRZ-EP-R7 is specified for the extended temperature range of −40°C to +125°C (EP grade). Both ranges should be confirmed against the latest manufacturer datasheet revision for the specific orderable part number.