ADM3050EBRIZ
아날로그 디바이스(주)
- Lifecycle
- Active
- Stock
- 5255 PCS
- Package
- SOIC-8
- Series
- 인터페이스 - 드라이브, 수신기, 트랜시버
ADM3050EBRIZ과 ADM3067ETRZ-EP-R7에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADM3050EBRIZ and ADM3067ETRZ-EP-R7 are not functionally interchangeable. The ADM3050EBRIZ is an isolated CAN transceiver, while the ADM3067ETRZ-EP-R7 is a non-isolated RS-485/RS-422 transceiver, so they serve fundamentally different interface and isolation roles. Substitution is not recommended without a full system-level redesign.
아날로그 디바이스(주)
아날로그 디바이스(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADM3050EBRIZ | ADM3067ETRZ-EP-R7 | Why it matters |
|---|---|---|---|
| Function / Protocol | Isolated CAN transceiver (CAN FD capable) | Isolated RS-485/RS-422 transceiver | These devices serve different bus protocols (CAN vs RS-485), so they are not functionally interchangeable in a given network. |
| Data Rate | Up to 12 Mbps (CAN FD) | Up to 500 kbps | Maximum signaling speed determines whether the part meets the bandwidth requirements of the application. |
| Isolation Rating | 5 kV rms (galvanic isolation) | 5 kV rms (galvanic isolation) | Isolation voltage rating is critical for safety and ground-loop immunity in industrial and medical systems. |
| Supply Voltage | 5 V (single supply) | 3.0 V to 5.5 V | Supply range affects compatibility with the host logic and power rail design. |
| Duplex / Channel Configuration | Half-duplex CAN (single channel) | Half-duplex RS-485 (single channel) | The bus topology and driver/receiver arrangement must match the network architecture. |
| Operating Temperature Range | -40 °C to +125 °C | -55 °C to +125 °C (EP grade) | Extended temperature range matters for harsh-environment and enhanced-product (EP) applications. |
| Package | 20-lead SOIC (wide body) | 14-lead SOIC | Footprint and pin count must match the PCB layout for a drop-in replacement. |
| Fail-Safe Receiver | Yes (bus idle / open / short fail-safe) | Yes (true fail-safe) | Fail-safe behavior ensures a defined logic state when the bus is undriven, preventing communication errors. |
| ESD Protection (Bus Pins) | ±8 kV contact / ±15 kV air (IEC 61000-4-2) | ±8 kV contact / ±15 kV air (IEC 61000-4-2) | Robust ESD protection improves reliability in electrically noisy industrial environments. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADM3050EBRIZ | ADM3067ETRZ-EP-R7 |
|---|---|---|
| Supplier | - | Analog Devices Inc. |
| Part Status | Active | Active |
| Type | Transceiver, Isolated | Transceiver |
| Protocol | CAN | RS485 |
| Number of Drivers/Receivers | 1/1 | 1/1 |
| Duplex | - | Full |
| Receiver Hysteresis | 150 mV | 30 mV |
| Data Rate | 12Mbps | 50Mbps |
| Voltage - Supply | 0.5V ~ 6V | 3V ~ 5.5V |
| Operating Temperature | -40°C ~ 125°C | -55°C ~ 125°C |
| Mounting Type | Surface Mount | Surface Mount |
| Series | iCoupler® | - |
The ADM3050EBRIZ is a 5 kV rms isolated CAN FD transceiver compliant with ISO 11898-2:2016, supporting data rates up to 12 Mbps. The ADM3067ETRZ-EP-R7 is a 3.3 V to 5 V RS-485/RS-422 transceiver with ±15 kV ESD protection (IEC 61000-4-2) and data rates up to 50 Mbps, designed for enhanced product (EP) applications. They serve different bus protocols (CAN FD vs. RS-485/RS-422) and are not functionally interchangeable.
No. The ADM3050EBRIZ is supplied in a 16-lead SOIC_W (wide-body) package, while the ADM3067ETRZ-EP-R7 is supplied in an 8-lead SOIC_N package. Pin counts, pin functions, and PCB land patterns differ, so they cannot be dropped into the same footprint.
The ADM3050EBRIZ operates from a single 5 V supply on VCC1 (logic side) and VCC2 (bus side) with integrated isolated DC-to-DC conversion. The ADM3067ETRZ-EP-R7 operates from a 3.3 V to 5 V supply on a single VCC rail. Designs must match the respective supply architecture; the ADM3067ETRZ-EP-R7 does not provide galvanic isolation.
Correct. The ADM3050EBRIZ is a signal-isolated CAN FD transceiver rated for 5 kV rms isolation per UL 1577 and CSA, with reinforced isolation suitable for safety-critical and high-noise environments. The ADM3067ETRZ-EP-R7 is a non-isolated RS-485/RS-422 transceiver; any isolation required in its application must be provided externally.
The ADM3050EBRIZ supports CAN FD per ISO 11898-2:2016 at data rates up to 12 Mbps. The ADM3067ETRZ-EP-R7 supports RS-485/RS-422 at data rates up to 50 Mbps. The applicable bus standard and maximum data rate must be matched to the system protocol; neither device can substitute for the other's protocol.
The ADM3067ETRZ-EP-R7 specifies ±15 kV ESD protection on the RS-485 bus pins per IEC 61000-4-2. The ADM3050EBRIZ specifies ESD protection on the CAN bus pins per the datasheet (contact and air discharge ratings per IEC 61000-4-2). Designers should consult the respective manufacturer datasheets for exact ESD, EFT, and surge ratings before finalizing protection circuitry.
The ADM3067ETRZ-EP-R7 is an enhanced product (EP) grade specified over the −55°C to +125°C operating temperature range. The ADM3050EBRIZ is specified over the −40°C to +125°C industrial temperature range. Applications requiring the extended −55°C low-end limit should verify the ADM3050EBRIZ's suitability against its datasheet ratings.
No. The ADM3067ETRZ-EP-R7 is an RS-485/RS-422 transceiver and does not implement the CAN or CAN FD physical layer defined by ISO 11898-2:2016. It cannot transmit or receive CAN FD frames, and it lacks the ADM3050EBRIZ's integrated galvanic isolation. Substitution would require a complete redesign of the bus interface.
For an isolated CAN FD interface, select the ADM3050EBRIZ, which integrates 5 kV rms isolation and ISO 11898-2:2016 CAN FD transceiver functionality in a single 16-lead SOIC_W package. For a high-speed, non-isolated RS-485/RS-422 interface requiring up to 50 Mbps and ±15 kV ESD protection over −55°C to +125°C, select the ADM3067ETRZ-EP-R7 in its 8-lead SOIC_N package.