ADS1282HIPWR
텍사스 인스트루먼트(주)
- Lifecycle
- Active
- Stock
- 5203 PCS
- Series
- 데이터 수집 - 아날로그 변환기(ADC)
ADS1282HIPWR과 ADS1246IPW에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADS1246IPW and ADS1282HIPWR are not functionally interchangeable. Although both are single-channel delta-sigma ADCs in TSSOP packages, they differ fundamentally in resolution, interface protocol, supply architecture, and target application class, so the ADS1282HIPWR cannot serve as a direct substitute for the ADS1246IPW without a full system redesign.
텍사스 인스트루먼트(주)
텍사스 인스트루먼트(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1246IPW | ADS1282HIPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 31 | Higher resolution enables finer measurement of small signal changes, which is critical for precision sensing applications. |
| Number of Input Channels | 1 (single-ended/differential) | 2 (differential) | Channel count determines how many signal sources can be measured without external multiplexing. |
| Maximum Sample Rate | 2 kSPS | 4 kSPS | Sample rate limits the bandwidth of signals that can be accurately digitized. |
| Interface Type | SPI | SPI | A compatible serial interface simplifies drop-in replacement and firmware reuse. |
| Supply Voltage (Analog) | 2.7 V to 5.25 V | 4.75 V to 5.25 V (analog), 2.7 V to 3.6 V (digital) | Supply range affects compatibility with the system power rail and low-voltage operation. |
| PGA / Gain Stage | Yes (PGA, gains 1 to 128) | Yes (PGA, gains 1 to 64) | An integrated PGA allows direct connection of low-level sensors without external amplification. |
| Package | TSSOP-16 | TSSOP-28 | Package footprint and pin count must match the PCB layout for physical substitutability. |
| Operating Temperature Range | -40 °C to +105 °C | -40 °C to +85 °C | Temperature range determines suitability for harsh or industrial environments. |
| Input Type | Single-ended or differential | Differential | Input configuration affects sensor wiring flexibility and noise immunity. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1282HIPWR | ADS1246IPW |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 31 | 24 |
| Sampling Rate (Per Second) | 4k | - |
| Number of Inputs | 2 | 1 |
| Input Type | Differential | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | ADC | MUX-PGA-ADC |
| Number of A / D Converters | 1 | - |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External, Internal |
| Voltage - Supply, Analog | 5V | 2.7V ~ 5.25V |
| Voltage - Supply, Digital | 1.65V ~ 3.6V | 2.7V ~ 5.25V |
| Features | PGA | PGA, Temperature Sensor |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 105°C |
| Mounting Type | Surface Mount | - |
| Base Product Number | ADS1282 | - |
| Sampling Rate(Per Second) | - | 2k |
| Number of A/D Converters | - | 1 |
The ADS1246IPW is a 24-bit, single-channel delta-sigma ADC in a 16-pin TSSOP package, while the ADS1282HIPWR is a 31-bit, dual-channel delta-sigma ADC in a 28-pin TSSOP package. The ADS1282H is designed for high-resolution seismic and energy exploration applications with a programmable gain amplifier and dual-channel simultaneous sampling, whereas the ADS1246 is a general-purpose low-noise ADC for sensor measurement.
No. The ADS1246IPW uses a 16-pin TSSOP (PW) package, and the ADS1282HIPWR uses a 28-pin TSSOP (PW) package. They are not pin-compatible and cannot be interchanged on the same PCB land pattern.
The ADS1246IPW provides 24-bit resolution with programmable data rates from 5 SPS to 2 kSPS. The ADS1282HIPWR provides 31-bit resolution with data rates from 250 SPS to 4 kSPS. These specifications are documented in the respective Texas Instruments datasheets.
The ADS1246IPW is a single-channel ADC with a flexible input multiplexer supporting differential and single-ended inputs. The ADS1282HIPWR is a dual-channel ADC with two simultaneous-sampling differential input channels, each with its own programmable gain amplifier.
No. The ADS1246IPW operates from an analog supply of 2.7 V to 5.25 V and a digital supply of 2.7 V to 5.25 V. The ADS1282HIPWR operates from an analog supply of 4.75 V to 5.25 V and a digital supply of 1.8 V to 3.6 V. Designers must verify supply rails against the respective datasheets.
No. The two devices differ in package pin count, resolution, channel count, supply requirements, and data rate ranges. A direct drop-in replacement is not possible; any substitution requires a full redesign and validation against the target application requirements.
The ADS1246IPW is typically used in precision sensor measurement, temperature and pressure sensing, and industrial process control. The ADS1282HIPWR is targeted at high-resolution seismic data acquisition, energy exploration, and geophysical instrumentation requiring dual-channel simultaneous sampling.