ADS1259IPWR
텍사스 인스트루먼트(주)
- Lifecycle
- Active
- Stock
- 6414 PCS
- Package
- TSSOP-20
- Series
- 데이터 수집 - 아날로그 변환기(ADC)
ADS1259IPWR과 ADS1222IPWRG4에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The ADS1259IPWR and ADS1222IPWRG4 are not drop-in replacements for one another. They differ in resolution, architecture, input channel configuration, and package footprint, so substituting one for the other requires full schematic and layout redesign as well as firmware revalidation.
텍사스 인스트루먼트(주)
텍사스 인스트루먼트(주)
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1259IPWR | ADS1222IPWRG4 | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 24 | Both are 24-bit delta-sigma ADCs, so resolution alone does not differentiate them for substitutability. |
| Number of input channels | 1 (single-ended) | 2 (differential) | Channel count and input configuration determine how many signals can be measured and whether differential measurement is supported. |
| Maximum sample rate | 14 kSPS | 2 kSPS | Sample rate limits the bandwidth of signals that can be accurately digitized; the ADS1259 supports significantly faster conversion. |
| Interface type | SPI | SPI | Both use SPI, so the host microcontroller interface is compatible, easing drop-in replacement at the digital level. |
| Supply voltage (analog) | 5 V (4.75 V to 5.25 V) | 2.7 V to 5.5 V | The wider analog supply range of the ADS1222 allows operation at lower voltages, affecting system power design and compatibility. |
| Package | TSSOP-20 | TSSOP-16 | Different pin counts and footprints mean the PCB layout must be redesigned; they are not pin-compatible. |
| Operating temperature range | -40°C to +105°C | -40°C to +85°C | The wider temperature range of the ADS1259 suits harsher environments, while the ADS1222 is limited to standard industrial conditions. |
| Internal PGA / gain | No (external gain) | Yes (PGA, gain 1 to 128) | An integrated PGA allows direct amplification of small sensor signals, simplifying the analog front end for low-level inputs. |
| Input voltage range | 0 V to VREF (unipolar) | Differential, ±VREF/gain | Input range and polarity determine whether the ADC can directly digitize bipolar or only unipolar signals without external conditioning. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1259IPWR | ADS1222IPWRG4 |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Discontinued at Digi-Key |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 14k | 240 |
| Number of Inputs | 1 | 2 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | ADC | MUX-ADC |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External |
| Voltage - Supply, Analog | 5V | 2.7V ~ 5.5V |
| Voltage - Supply, Digital | 2.7V ~ 5.25V | 2.7V ~ 5.5V |
| Features | PGA | Temperature Sensor |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
The ADS1259IPWR is a 24-bit, 14.4-kSPS delta-sigma ADC with an integrated low-noise PGA and a precision voltage reference, designed for high-resolution industrial measurement. The ADS1222IPWRG4 is a 24-bit, 2-kSPS delta-sigma ADC with a fixed-gain PGA and no integrated reference, intended for lower-speed, cost-sensitive sensor applications. The ADS1259 offers higher throughput and integrated reference, while the ADS1222 provides lower power and a smaller feature set.
No. The ADS1259IPWR is supplied in a TSSOP-20 package, while the ADS1222IPWRG4 is supplied in a TSSOP-16 package. The pin counts and pin functions differ, so they are not drop-in replacements and require different PCB land patterns.
The ADS1259IPWR supports data rates up to 14.4 kSPS in its high-speed mode. The ADS1222IPWRG4 supports data rates up to 2 kSPS. The ADS1259 is therefore better suited for applications requiring faster signal acquisition, while the ADS1222 targets low-speed precision sensing.
No. The ADS1259IPWR integrates a precision voltage reference, which reduces external component count. The ADS1222IPWRG4 does not include an integrated reference and requires an external reference voltage for ratiometric or absolute measurements.
The ADS1259IPWR includes a low-noise PGA with selectable gains of 1 to 128, supporting direct connection of low-level sensors. The ADS1222IPWRG4 includes a fixed-gain PGA of 1 to 128 as well, but its noise and throughput performance are optimized for lower-speed operation. Designers should compare noise density and effective resolution at the target gain and data rate.
The ADS1259IPWR operates from an analog supply of 5 V (with a digital supply of 2.7 V to 5.25 V) and typically consumes about 13 mW at 14.4 kSPS. The ADS1222IPWRG4 operates from a single 2.7 V to 5.5 V supply and typically consumes about 1.2 mW at 2 kSPS. The ADS1222 is significantly lower power, consistent with its lower throughput.
The ADS1259IPWR is generally more suitable for high-resolution industrial measurement because it combines 24-bit resolution, up to 14.4 kSPS throughput, a low-noise PGA, and an integrated precision reference. The ADS1222IPWRG4 is better suited to lower-speed, lower-power sensor interfaces where an external reference is acceptable.
No. Direct replacement is not possible without redesign because the two devices differ in package (TSSOP-16 vs TSSOP-20), pinout, maximum sample rate, reference architecture, and supply/power characteristics. Any substitution must be validated against the manufacturer datasheets and the target system requirements.