AMC1300DWVR vs AMC1302DWV

AMC1300DWVR과 AMC1302DWV에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AMC1302DWV is a functional replacement candidate for the AMC1300DWVR in isolated current-sensing applications, sharing the same isolated amplifier architecture, SOIC-8 (DWV) footprint, and 5 V supply rail. However, the two devices differ in input voltage range, gain, and bandwidth, so the replacement is valid only after confirming that the host system's shunt signal level, gain chain, and dynamic response requirements are satisfied by the AMC1302DWV's narrower input range and higher fixed gain.

Package and Pinout High match
Input Voltage Range Validation required
Fixed Gain Validation required
Bandwidth Validation required

Parts at a glance

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AMC1300DWVR AMC1302DWV Why it matters
Input Voltage Range ±250 mV ±50 mV Defines the differential signal span the isolated amplifier can accept; a smaller range suits shunt-based current sensing with lower full-scale drop.
Fixed Gain 8.2 V/V 41 V/V Determines the output scaling relative to input; different gain changes the required ADC full-scale and signal conditioning.
Input Offset Voltage (max) ±0.3 mV ±0.05 mV Lower offset improves measurement accuracy at low currents; a significant difference affects precision in shunt sensing.
Input Bias Current ±30 µA ±25 µA Bias current flowing through the shunt and filter resistors creates offset error; lower bias current improves accuracy.
Common-Mode Input Range -150 mV to 320 mV (relative to GND1) -160 mV to 320 mV (relative to GND1) Limits the allowable shunt common-mode voltage; slight differences affect headroom in high-side sensing topologies.
Isolation Rating (UL1577) 5000 Vrms (reinforced) 5000 Vrms (reinforced) Determines safety isolation capability; identical ratings mean both meet the same reinforced isolation requirements.
Supply Voltage (VDD1 / VDD2) 3.0 V to 5.5 V (both sides) 3.0 V to 5.5 V (both sides) Defines compatible supply rails; identical ranges allow drop-in use in the same power architecture.
Bandwidth 100 kHz 100 kHz Sets the maximum signal frequency the amplifier can accurately pass; identical bandwidth supports similar control-loop speeds.
Package 8-SOIC (wide body, 5.85 mm) 8-SOIC (wide body, 5.85 mm) Footprint and creepage/clearance depend on package; identical packages allow PCB layout reuse.
Operating Temperature Range -40°C to +125°C -40°C to +125°C Defines environmental limits; identical ranges ensure equivalent robustness in industrial applications.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AMC1300DWVR AMC1302DWV
Supplier - Texas Instruments
Part Status Active Active
Type Isolation Isolation
Applications Current Sensing, Power Management Current Sensing, Power Management
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the key differences between the AMC1300DWVR and the AMC1302DWV?

The AMC1300DWVR is an isolated amplifier with a fixed gain of 8.2 and a ±250 mV input range, while the AMC1302DWV is an isolated amplifier with a fixed gain of 41 and a ±50 mV input range. Both are single-channel, reinforced-isolated amplifiers in a 5.85 mm × 7.5 mm SOIC-8 (DWV) package, but they differ in input voltage range, gain, and specified linearity and offset performance.

Are the AMC1300DWVR and AMC1302DWV pin-compatible?

Yes. Both devices are offered in the same 8-pin SOIC (DWV) package with the same pinout: VDD1, INP, INN, GND1 on the input side and VDD2, OUTP, OUTN, GND2 on the output side. This allows a common PCB footprint, but the different gain and input range must be validated for the target design.

What isolation rating do the AMC1300DWVR and AMC1302DWV provide?

Both devices are reinforced isolated amplifiers rated for 5000 V RMS isolation per UL 1577 and provide a working voltage of 1500 V DC per VDE V 0884-11 (VDE 0884-11). They are intended for isolated current and voltage sensing in industrial and motor-drive applications.

What input voltage range does each device support?

The AMC1300DWVR supports a linear input range of ±250 mV with a fixed gain of 8.2, making it suitable for shunt-based current sensing with larger shunt voltage drops. The AMC1302DWV supports a linear input range of ±50 mV with a fixed gain of 41, intended for very low shunt voltage drops to minimize shunt power dissipation.

Can the AMC1302DWV directly replace the AMC1300DWVR in an existing design?

Not without redesign validation. Although the package and pinout are identical, the AMC1302DWV has a much smaller input range (±50 mV vs ±250 mV) and a higher gain (41 vs 8.2). The shunt resistor value, signal scaling, and downstream ADC or controller gain must be recalculated and verified against the datasheet specifications.

What are the typical applications for the AMC1300DWVR and AMC1302DWV?

Both are used for isolated current and voltage sensing in motor drives, inverters, solar inverters, and industrial power supplies. The AMC1300DWVR is typically used where a larger shunt voltage is acceptable, while the AMC1302DWV is used where very low shunt voltage drop and low power dissipation are required.

What supply voltage do the AMC1300DWVR and AMC1302DWV require?

Both devices operate with a high-side supply (VDD1) of 3.0 V to 5.5 V and a low-side supply (VDD2) of 3.0 V to 5.5 V, allowing direct connection to 3.3 V or 5 V logic and ADC inputs on the isolated side.

How do the offset and gain error specifications compare between the two devices?

The AMC1300DWVR specifies an input offset error of ±1 mV (max) and a gain error of ±0.3% (max). The AMC1302DWV specifies an input offset error of ±0.2 mV (max) and a gain error of ±0.3% (max). The tighter offset of the AMC1302DWV is consistent with its smaller ±50 mV input range.