AFE58JD28ZAV
텍사스 인스트루먼트(주)
- Lifecycle
- Active
- Stock
- 7063 PCS
- Package
- NFBGA-289
- Series
- 데이터 수집 - 아날로그 프런트엔드(AFE)
AFE58JD28ZAV과 AFE5816ZAV에 대한 심층 비교를 통해 두 제품의 사양 및 주요 특징에 대한 유용한 정보를 얻을 수 있습니다. RoHS 준수 여부, REACH 인증 상태, 시리즈, 장착 방식, 패키지 유형 및 기타 관련 특성을 포함한 중요한 요소들을 자세히 다룹니다. 두 제품의 차이점을 나란히 제시함으로써 부품 선택이 간소화되어 특정 용도에 가장 적합한 옵션을 쉽게 선택할 수 있습니다.
Replacement verdict
The AFE58JD28ZAV is a viable functional replacement candidate for the AFE5816ZAV, sharing the same 8-channel ultrasound AFE architecture, 14-bit ADC resolution, and 16 mm × 16 mm NFBGA-289 footprint. Designers must validate the higher per-channel power consumption and the extended operating temperature range against the target system's thermal and environmental requirements before committing to a drop-in substitution.
텍사스 인스트루먼트(주)
텍사스 인스트루먼트(주)
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AFE58JD28ZAV | AFE5816ZAV |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 12, 14 | 12, 14 |
| Number of Channels | 16 | 16 |
| Power (Watts) | 64 mW | 94 mW |
| Voltage - Supply, Analog | 3.15V ~ 3.6V | 1.7V ~ 2V, 3V ~ 3.3V |
| Mounting Type | Surface Mount | Surface Mount |
| Voltage - Supply, Digital | - | 1.15V ~ 1.25V, 1.7V ~ 1.9V |
The AFE5816ZAV and AFE58JD28ZAV are both Texas Instruments fully integrated analog front-end (AFE) devices for ultrasound imaging systems. Each integrates a low-noise amplifier (LNA), voltage-controlled attenuator (VCA), programmable gain amplifier (PGA), anti-aliasing filter, and a 14-bit analog-to-digital converter (ADC) across multiple channels in a single package.
The AFE5816ZAV integrates 16 channels, while the AFE58JD28ZAV integrates 8 channels. This difference directly affects the number of transducer elements each device can support and the overall system partitioning in an ultrasound front end.
Both devices are offered in a 289-ball NFBGA (ZAV) package. However, because the AFE5816ZAV provides 16 channels and the AFE58JD28ZAV provides 8 channels, the pin functions and channel-to-ball assignments differ, so the two are not pin-for-pin drop-in replacements despite sharing the same package outline.
Both the AFE5816ZAV and AFE58JD28ZAV incorporate a 14-bit ADC with a maximum sampling rate of 65 MSPS per channel, supporting the bandwidth and dynamic range requirements typical of medical ultrasound receive chains.
Because the AFE5816ZAV integrates 16 channels and the AFE58JD28ZAV integrates 8 channels, total power scales with channel count. Per-channel power consumption is comparable between the two devices, so the 16-channel AFE5816ZAV dissipates roughly twice the total power of the 8-channel AFE58JD28ZAV under equivalent per-channel operating conditions.
No, they are not direct substitutes. The AFE58JD28ZAV provides only 8 channels versus 16 channels in the AFE5816ZAV, and the channel-to-ball assignments differ within the shared 289-ball NFBGA package. A substitution would require redesign of the channel mapping, PCB layout, and system partitioning, validated against the respective TI datasheets.
Both devices provide a low-voltage differential signaling (LVDS) digital output interface for the 14-bit ADC data, supporting high-speed serial data transfer to an FPGA or digital signal processor in the ultrasound receive path.